Patch Name: PHSS_7009 Patch Description: s700_800 10.10 PerfView B.04.02 Creation Date: 96/07/03 Post Date: 96/07/15 Hardware Platforms - OS Releases: s700: 10.10 s800: 10.10 Products: PerfView B.04.01 Filesets: PerfView.PV PerfView.PV-PLATFORM-HP Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_7009 Symptoms: PHSS_7009: Multiple symptoms are fixed with this patch: 1. pv command line using range or -b and -e produces incorrect graph 2. saved graph template won't draw; pv12-5 ...metrics not available 3. system-type of "SunOS" doesn't work in PV tools menu 4. graphs are different than defined templates when used from alarmdef file 5. clicking last metric in selection box twice causes fatal error 6. print of application drill down data prints "1076391584" for App name 7. print of drill down tabular data doesn't print all rows 8. pv doesn't include postscript commands when printing tabular data 9. print drill process needs to be set w/ width 256 (printer) and 2048(file) 10. intermittantly receive "Requested metrics not available" clicking alarm 11. coredump when drawing class compare from mpe pv 3.0 agent system 12. alarm graph doesn't match default graph w/ other datasources selected 13. when drawing "alarm" graph > 1 datasource saved, opens only one 14. selecting another system after initial draw of class compare ... can cause coredump 15. pv fails when selecting "system compare" against extracted logfile that doesn't include global data 16. "application history" graph applied towards extracted logfile shows incorrect application instance list 17. pv coredumps when printing "class compare" graph with > 14 items 18. the 8 metrics displayed on graph should be the only ones in the printed graph legend 19. long application/datasource names are omitted on printed graph legend 20. legend labels on printed graphs are incomplete 21. fatal error in pv planner attempting to forecast w/ business units 22. problem with 2nd business unit field not taking over from first 23. default start/stop times for forecast from extracted logfile are incorrect 24. pv graphs may lose data labels if exclude weekends is set 25. printing drill down process gives only header information 26. when excluding holidays (Global Time Settings) data is excluded 27. need summarization indication on graph printout 28. overlap occurs with timestamps on graph printout x-axis 29. intermittant "garbaged" display can appear on printed graphs 30. pv unable to receive alarms from multi-homed system (multi-lan) 31. mwa alarms not getting through to pv monitor; alarmlog corrupted 32. message pv1 00-13from pvalarmd must include the agent IP address 33. printing graph to file using command line creates zero byte file 34. pvalarmd -size option not documented in pvalarmd -? or the man page 35. perfview will not print if paper size A4 is selected pe98-1 36. incorrect placement of pv add-on keys when trial software is run 37. pv batch commands should not require the DISPLAY variable 38. pv -h, to get cmd line syntax, doesnt work w/o DISPLAY export 39. pv aborts if drawing >=2 data sources and at least 1 source is empty 40. pvsysdb usage statement should contain all switches included in man page 41. printing drill down to file/printer truncates at 80 characters and 58 lines 42. standard templates are not found when connecting to mpe/ix 3.0 agent 43. on-item help says help volume is missing for mpe/ix 3.0 agent 44. command line switch definition for -graph not correct 45. command line syntax for -metric switch using DSI needs better explanation 46. errors in pv online help (-prn vs -print) 47. business unit formatting guidelines is incorrect in online help 48. need to reword error pv88-2 to accurately reflect error 49. need documentation (online/manpage) explaining fix for multi-homed system 50. MPE alarm graph hang intermittantly in "retrieving data" state 51. When more than 1 DSI datasource is included in a template,metrics gone 52. PerfView Analyzer expired trial message is displayed erroneously 53. PV 3.0 agent selection box doesn't include help text 54. pvalarmxp start and end times don't work properly Defect Description: PHSS_7009: See Symptoms. SR: 5003312116 D500246207 D500252130 D500252403 D500252775 D500253500 D500253518 D500253526 D500256040 D500256057 D500257121 D500257501 D500258095 D500258590 D500259366 D500259374 1653156356 1653156364 D500244566 D500246215 D500250035 D500253237 D500254011 D500254417 D500256818 D500258426 D500259614 D500259697 D500259705 D500258194 D500258210 D500258111 D500246165 D500247338 D500251363 D500251587 D500251868 D500242768 D500243980 D500252122 D500248609 D500251108 D500251553 1653161729 1653166835 5003314237 D500251579 D500254144 D500258202 D500261750 D500261800 D500248856 D500262493 5003319111 Patch Files: /opt/perf/bin/pv /opt/perf/bin/pvalarmd /opt/perf/bin/pvalarmd3 /opt/perf/bin/pvalarmxp /opt/perf/bin/pvglance /opt/perf/bin/pvsysdb /opt/perf/lib/nls/msg/C/pvmsgs /opt/perf/ReleaseNotes/Pv.patch /opt/perf/help/pv/C/pvhelp.hv /opt/perf/help/pv/C/pvhelp.hvk /opt/perf/help/pv/C/pvhelp00.ht /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/metrics.hv /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/metrics.hvk /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/metrics00.ht /opt/perf/man/man1/pvalarmd.1 /opt/perf/man/man1/pvalarmxp.1 /opt/perf/man/man1/pvsysdb.1 /opt/perf/man/man1/pv.hosts.1 what(1) Output: /opt/perf/bin/pv: pv B.04.02 07/02/96 HP-UX 10.0 =*= /opt/perf/bin/pvalarmd: pvalarmd B.04.02 07/02/96 HP-UX 10.0 =*= /opt/perf/bin/pvalarmd3: pvalarmd3 B.04.02 07/02/96 HP-UX 10.0 =*= /opt/perf/bin/pvalarmxp: pvalarmxp B.04.02 07/02/96 HP-UX 10.0 =*= /opt/perf/bin/pvglance: None /opt/perf/bin/pvsysdb: pvsysdb B.04.02 07/02/96 HP-UX 10.0 =*= /opt/perf/lib/nls/msg/C/pvmsgs: None /opt/perf/ReleaseNotes/Pv.patch: B.04.02 PerfView Release Notes 07/02/96 /opt/perf/help/pv/C/pvhelp.hv: PerfView 10.0 Help B.04.02 04/15/96 =*= PerfView Help B.04.00 11/07/95 =*= /opt/perf/help/pv/C/pvhelp.hvk: None /opt/perf/help/pv/C/pvhelp00.ht: None /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/metrics.hv: PerfView Help B.04.02 04/15/96 =*= /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/metrics.hvk: None /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/metrics00.ht: None /opt/perf/man/man1/pvalarmd.1: None /opt/perf/man/man1/pvalarmxp.1: None /opt/perf/man/man1/pvsysdb.1: None /opt/perf/man/man1/pv.hosts.1: None cksum(1) Output: 876868303 3717117 /opt/perf/bin/pv 4233647328 173007 /opt/perf/bin/pvalarmd 3832160490 177167 /opt/perf/bin/pvalarmd3 640685889 160675 /opt/perf/bin/pvalarmxp 2467679399 10760 /opt/perf/bin/pvglance 3257321541 131847 /opt/perf/bin/pvsysdb 850845787 33015 /opt/perf/lib/nls/msg/C/pvmsgs 2566368178 9637 /opt/perf/ReleaseNotes/Pv.patch 2776921638 88787 /opt/perf/help/pv/C/pvhelp.hv 1910448828 21991 /opt/perf/help/pv/C/pvhelp.hvk 3799688162 348995 /opt/perf/help/pv/C/pvhelp00.ht 3192239312 5901 /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/ metrics.hv 2308875519 1378 /opt/perf/help/pv/C/pvmetrics/MPE-3.0-Agent/ metrics.hvk 4045968685 30171 /opt/perf/help/pv/C/pvmetrics/ MPE-3.0-Agent/metrics00.ht 2055720313 1271 /opt/perf/man/man1/pvalarmd.1 697674304 1608 /opt/perf/man/man1/pvalarmxp.1 1736419263 1077 /opt/perf/man/man1/pvsysdb.1 2194940479 1166 /opt/perf/man/man1/pv.hosts.1 Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: None Patch Package Size: 4870 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_7009 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_7009.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_7009.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. The cluster clients must be shut down as described in step 5b. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_7009. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_7009.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_7009.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: This patch should be applied to PerfView version B.04.01 only.