Patch Name: PHSS_26341 Patch Description: s700_800 10.20 OV OB4.10 patch - CC packet Creation Date: 02/04/22 Post Date: 02/04/25 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OmniBackII A.04.10 Filesets: OMNIBACK-II.OMNI-HPUX-P,A.04.10 Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_26341 Symptoms: PHSS_26341: Id = HSLco31198 SR: H555006778 Restore of Oracle7 database to a different host (backup host and target host are not the same) fails with the following error message: "grep: can't open /etc/opt/omni/oracle/rcs/.rcs" Id = HSLco31665 SR: H555006875 When files are selected for restore and restore is started, RSM reports: "Error starting VBDA on : Maximum number of files/directories specified => DA will not be started. Try to specify less files/directories and restart backup." Id = HSLco31733 SR: H555006893 Additional dates added to periodic backup schedule after 13 months. Id = HSLco31949 SR: H555006942 OmniBack II A.04.10 GUI abnormally ends when trying to connect to OmniBack II A.04.00 Cell Manager. Id = HSLco32409 SR: H555007048 GUI shows incorrect number of SQL objects for the system. Id = JAGad95458 SR: 8606226389 Compress option for the SAP integration in GUI is enabled. Id = HSLco32637 SR:H555007125 Printing in OmniBack II 4.x HP-UX GUI does not work. Id = HSLco32864 SR:H555007211 Linux clients can not be updated from GUI. Id = HSLco32873 SR:H555007218 If you try to restore files in interval that does not include full backup the following error appears: "DB unknown error". Id = HSLco33095 SR:H555007294 Device wizard text update is not working on HPUX 4.X GUI. Id = HSLco33471 SR:H555007472 Split pre-exec and post-exec scripts in the EMC integration are grayed out. Id = JAGae02797 SR:8606233574 Comments can not be added to RMAN script via OmniBack if '#' is specified before comment. Id = HSLco31357 SR:H555006818 GUI crashes during object messages check. Id = HSLco31031 SR:H555006752 During client upgrade it is not possible to automatically select all the hosts for the same Installation Server. Defect Description: PHSS_26341: Id = HSLco31198 When restoring Oracle7 tablespace that is backed up on one backup host to another target Oracle client, the Restore Session Manager copies the rcs file to the backup host instead of target host. Resolution: The rcs files are properly restored to the target host. Id = HSLco31665 Files which are grayed out in GUI are excluded with option -exclude. Since the number of '-exclude' options is limited, this can cause restore to fail. Resolution: Handling of excluded files is changed. Id = HSLco31733 In next year the same date is not the same day in week. Scheduled dates after one year are just copied, so backups are scheduled on wrong days. Resolution: Days are correctly moved to next year. Id = HSLco31949 Any attempt to establish connection to OmniBack II A.04.00 Cell Manager from OmniBack II A.04.10 GUI, when having no permissions to do so, results in core dump of OmniBack II A.04.10 GUI. Resolution: Message "No permission" is displayed when one tries to connect to a system where one does not have sufficient permissions. Part of SSPUX410_004. Please see Special Installation Instructions. Id = HSLco32409 GUI incorrectly determines which SQL objects has already been added to SQL restore and which not. Consequently GUI may display no objects at all, though omnidb shows objects or the same object several times. Resolution: GUI now correctly determines which SQL objects have to be added to restore tree. Id = JAGad95458 The Release Notes state that compression is not supported for any of the database integrations. Resolution: The Compress option in GUI is disabled. Id = HSLco32637 Printing is not possible due to missing windu xprinter directory and *.drv files in OmniBack II installation. Resolution: Files are copied to the correct location. Id = HSLco32864 GUI expects Windows Installation Server for Linux client. However the right one is UNIX Installation Server. Resolution: Checking is improved with new macro for GUI. Id = HSLco32873 Selecting files for restore within interval that does not include the full backup will trigger an error in the list_full_rest_chain function. Resolution: The function marks an error and sends it to GUI, which will show a message: "You have chosen an interval which does not include all the sessions needed to compose a full restore chain. Please reconnect to the Cell Server". Please see Special Installation Instructions. Id = HSLco33095 When adding new device in GUI and device type is changed to SCSI library in first step of wizard, data format is not changed to interface type. Resolution: Window is invalidated and updated. Id = HSLco33471 Split pre-exec and post-exec scripts working with the EMC integration are disabled. Resolution: Split pre-exec and post-exec scripts working with the EMC integration are enabled again. Id = JAGae02797 OmniBack II uses '#' character for internal parsing. Resolution: Code is changed. New character is used for OmniBack II internal parsing. Id = HSLco31357 In case that object has large number of messages, GUI crashes during message check. Resolution: GUI is improved in order not to crash. Id = HSLco31031 During client upgrade it is not possible to automatically select all the hosts for the same Installation Server. Resolution: GUI is improved. SR: H555006893 H555006875 H555007211 8606226389 H555006778 H555007125 H555007218 H555007048 H555006752 H555007472 8606233574 H555006942 H555007294 H555006818 Patch Files: /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.04.10/ packet.Z /opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.04.10/ packet.Z what(1) Output: /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.04.10/ packet.Z: None /opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.04.10/ packet.Z: None cksum(1) Output: 2094295873 39812615 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux-1020/A.04.10/packet.Z 52878853 39841953 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux-11/A.04.10/packet.Z Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_26342: s700: 11.00 11.11 11.20 s800: 11.00 11.11 11.20 Patch Package Size: 77840 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_26341 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_26341.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_26341. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_26341.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_26341.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: PHSS_26341: NOTE! This Patch has to be installed on the Installation Server host. The User Interface must be redistributed to the client system(s) after the installation of the patch in order to get the fixes into effect. For distribution of the User Interface, refer to the OmniBackII Installation guide. PHSS_26341/PHSS_26342: NOTE! In order to get whole functionality of defect fix HSLco31949, Core patch PHSS_25964/PHSS_25965 (or later) has to be installed and applied as well. NOTE! Complete functionality of defect fix HSLco32873 will be available when patches PHSS_26349/PHSS_26350 (Core) and PHSS_25962/PHSS_25963 (Cell Server) are installed - or successors of them. Patch includes the following Site Specific Patches: SSPUX410_004