Patch Name: PHSS_26215 Patch Description: s700_800 10.X OV OB3.50 patch - SSEA packet Creation Date: 02/02/13 Post Date: 02/02/14 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.03.50 Filesets: OMNIBACK-II.OMNI-SSEA-P,A.03.50 Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_26215 Symptoms: PHSS_26215: Id = HSLco32218 SR: H555006986 Horc instance number is not configurable. Id = HSLco32253 SR: H555006993 SSEA agent reports disks in SIMPLEX state although they are in PAIR state in HORCM. Id = HSLco32264 SR: H555006994 OmniBack II SSEA Integration does not work with logical devices with XP LUN number greater than 128. Id = HSLco32274 SR: H555006996 Performance of SSEA integration drastically decreases after the installation of PHSS_25817/PHSS_25818. PHSS_25817: Id = JAGad48627 SR:8606179403 If preexec script fails OmniBack II by default just aborts the agent and exits. It does not run post-exec script or clean up. Id = NSMex04226 Restore fails with: "[Major] From: SYMA@ "" Time: