Patch Name: PHSS_25962 Patch Description: s700_800 10.20 OV OB4.10 patch - CS packet Creation Date: 02/04/04 Post Date: 02/04/16 Warning: 02/05/20 - This Critical Warning has been issued by HP. - PHSS_25962 introduces behavior such that, following the installation of patch PHSS_25962, AND after the system is rebooted, there may be problems communicating with the Media Management Database (MMDB). - The following symptoms may be observed: 1. Unable to start the Media Management Daemon (MMD) 2. The MMD will start, but all Omniback commands that access the MMDB will hang, and then error. For example: # /opt/omni/bin/omnimm -list_pools Time out occurred. System error: [4] Interrupted system call Additionally, stopping and then restarting the Omniback server processes does not free up the MMD. - This behavior is corrected in patch PHSS_26353 released today. Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OmniBackII A.04.10 Filesets: OMNIBACK-II.OMNI-CS,A.04.10 Automatic Reboot?: No Status: General Superseded With Warnings Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_25962 Symptoms: PHSS_25962: Id = HSLco31142 SR: H555006771 Load balancing is not working properly. Id = HSLco31145 SR: H555006772 Omniback database suddenly stops reporting any details about sessions. Id = HSLco31265 SR: H555006788 After the execution of a session with load balacing used, devices remain locked and cannot be used for later sessions. Id = HSLco31359 SR: H555006819 Forced ownership in datalist does not function properly. Id = HSLco31475 SR: H555006843 Backup Session Manager abnormally ends. Id = HSLco31629 SR: H555006868 Vault reporting does not work properly. Id = JAGad98695 SR: 8606229643 Changing any option for a DCBF directory resets all other values to default. Id = HSLco31067 SR: H555006757 "End of Session" e-mail notification does not specify datalist name for which it was created. Id = HSLco31942 SR: H555006939 Restore of Oracle 8 objects hangs. Id = HSLco31981 SR: H555006948 Cell Request Server abnormally ends periodically. Id = HSLco32089 SR: H555006968 The 'omnidbrestore -autorecover' fails with error: "Current medium is refused for restore. Aborting!" Id = HSLco32276 SR: H555006998 Using a "\" sign when setting RecoveryIndexDir option in global options file sometimes causes Backup Session Manager failure. Id = HSLco32499 SR: H555007081 "omnisv -start_mon" is inactive for 1 second between loops. Id = HSLco32614 SR: H555007115 Executing "omnidbutil -purge -filenames " fails with an error: "[Major] From: OMNIDBUTIL@ "" Time: