Patch Name: PHSS_24660 Patch Description: s700_800 10.X OV OB3.50 patch - CC packet Creation Date: 01/09/03 Post Date: 01/09/12 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.03.50 Filesets: OMNIBACK-II.OMNI-HPUX-P,A.03.50 OMNIBACK-II.OMNI-OTHUX-P,A.03.50 Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_24660 Symptoms: PHSS_24660: Id = NSMex03922 Listing of Oracle objects on GUI fails. Id = NSMex03986 Omnir core dumps. Id = NSMex04296 Backup scheduler shows incorrect dates. Id = NSMex04323 Command "omnimm -enter [slot_range]" returns invalid slot error. Id = NSMex04347 Restore to a different host fails with an error: "Can not stat script /usr/omni/bin/(null).". Id = NSMbb39907 Any attempt to change object format in Oracle8 RMAN script using OmniBack II GUI fails with the following error: "[12:1645] Format of RMAN channel names is not correct.". Id = HSLco20414 Device maintenance from command line is not sufficient. Id = NSMex03989 Command "omnirpt -report db_size -html -email " works improperly. Id = NSMex04439 omnib command ignores "-encode" option. Id = NSMbb38972 Exchange 2000 backup cannot be started from command line. PHSS_22850: Id = JAGad30352 "EMC Support" tab is not available in "Backup Specification - Options" GUI. Id = JAGad35002 If database integration in a MC/ServiceGuard cluster is backed up, the backup can report an error. Id = NSMex03419 After importing a tape from 2.55 to 3.50 cell some of the files can not be restored. Id = NSMex03475 Restore GUI does not display SAP objects, if two SAP instances with the same name are backed up on different host. Id = NSMex03505 a) When selecting restore of SAP object, message "Cannot browse from root" appears. b) When selecting restore from File System Restore Dialog GUI might core dump. Id = NSMex03658 Exit code of omniminit is incorrect. Id = NSMex03833 The options under Edit button are not accessible even if user has rights. Id = JAGad29457 Ownership incorrectly displayed within restore GUI. Id = JAGad33161 Datalists/barlists with EMC integration are incorrectly created. PHSS_22038: Id = NSMex03503 Users with only "Start Backup" privilege can delete datalists. Id = NSMex03511 "Send external" method always executes external script on Cell Manager system. Defect Description: PHSS_24660: Id = NSMex03922 Incorrect memory usage causes GUI to core dump whilst listing Oracle sessions. Resolution: Memory usage is improved. Id = NSMex03986 The omnir command causes a memory fault and core dumps if it is run with a long list of objects. Resolution: Omnir can handle long list of objects. Id = NSMex04296 Backup scheduler loses months prior to January, 2002. Resolution: Scheduler optimization improved. Id = NSMex04323 When executing "omnimm -enter [slot_range]" command a "0" is appended to slot range. This causes invalid slot error. Resolution: "omnimm -enter [slot_range]" command works properly. Id = NSMex04347 Restore GUI improperly sends empty pre- and post-exec options to Restore Session Manager. Resolution: Fix is implemented in Restore GUI. Id = NSMbb39907 It is impossible to define the object format in an Oracle8 RMAN script using the Omniback II GUI. Resolution: It is possible to change object format in Oracle8 RMAN script using OmniBack II GUI. Part of SSPUX350_031. Id = HSLco20414 Device enabling, disabling and status report can not be performed using OmniBack II command line. Resolution: New options "-disable_device", "-enable_device" and "-device" are added to omnimm, omniupload and omnidownload. Please see Special Installation Instructions for details about the usage of mentioned options. Part of SSPUX350_038. Id = NSMex03989 Command "omnirpt -report db_size -html -email " returns HTML code instead of formatted report. Resolution: Missing header is added to HTML report. Id = NSMex04439 omnib command ignores "-encode" option. Resolution: omnib command properly recognizes "-encode" option. Id = NSMbb38972 Exchange 2000 backup cannot be started from command line. Resolution: It is possible to start Exchange 2000 backup from command line. Part of SSPUX350_020. PHSS_22850: Id = JAGad30352 "EMC Support" tab is not available in "Backup Specification - Options" GUI, unless the cell_info entry for the Cell Manager has the "-emc" option. Resolution: xomnibackup now correctly checks cell_info file for "-emc" options. Id = JAGad35002 a )Windows NT GUI supports cluster import which creates additional attributes in the cell info file to mark cluster nodes and virtual servers. MC/SG clusters do not have such support yet. b) Motif GUI does not have any way to import cluster in the cell. Session Manager starts agent on certain machine and expects that the connection will come from that machine or a physical node on a cluster. If additional attributes in the cell info are not set then SM aborts the connection. Resolution: .util shell script has been enhanced to allow import of the cluster using Windows GUI. The script handles messages INFO_CLUS and INFO_CLUS1 which allow the import to happen. Please see Special Installation Instructions. Id = NSMex03419 OmniBack II 3.50 objects are case insensitive which is not true for the SAP objects backed up with 2.55 version. Object tape format is changed with 3.50 as well. These changes caused some SAP objects not to be displayed in the Restore GUI after importing the tape with SAP objects from 2.55 to 3.50. Resolution: Names are tape format are converted into OmniBack II 3.50 format after tape import from 2.55. Id = NSMex03475 Restore GUI does not display SAP objects, if two SAP instances with the same name are backed up on different host. Resolution: xomnirestore has been improved to show all object. Id = NSMex03505 a) When selecting restore of SAP object, message "Cannot browse from root" appears. b) Two different structures with the same name were defined. Resolution: xomnirestore has been improved. Id = NSMex03658 Exit code 0 is returned when the medium initialization fails with error: "This medium can be initialized only with force option specified." Resolution: Exit code of omniminit for failed operation is redefined. Id = NSMex03833 User rights are not properly interpreted. Resolution: User rights permissions has been modified. Id = JAGad29457 xomnirestore shows user name and group name for backed up objects. If users on different clients have different UID and GID wrong user will be shown in version browser. Resolution: New option GUIShowUID has to be set in file: /etc/opt/omni/options/global on Cell Manager host. GUIShowUID= where means: - 0, GUI converts UIDs and GIDs to strings - 1, only UIDs and GIDs numbers will be showen Part of SSPUX350_013. Id = JAGad33161 Options for EMC integration are incorrectly saved when datalist/barlist is created with Motif GUI. Resolution: EMC type resolving has been improved. Part of SSPUX350_013. PHSS_22038: Id = NSMex03503 User rights are not properly checked. Resolution: User rights checking is properly improved. Id = NSMex03511 Execution of external script can not be prevented. Resolution: Omnirpt is changed so that the execution of "Send external" method can be controlled by adding a line ExternalScriptMode= in Global Options file, where means: - 0, no checking is performed - 1, script can be executed only in bin directory - 2, executing of external scripts is not allowed. SR: H555004942 H555003134 8606179663 H555005709 H555005547 H555005845 H555004369 H555004246 H555004381 8606160131 8606161034 8606163859 B554000788 8606165711 B554000550 H555003728 B554000606 B554000634 Patch Files: /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/ncr/i386/mp-ras/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/gpl/i386/linux/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/sco/i386/unixware/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/sequent/i386/dynix/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/sgi/mips/irix/A.03.50/packet.Z /opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/siemens/r400/sinix/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/sun/sparc/solaris/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/sun/sparc/solaris-26/A.03.50/ packet.Z /opt/omni/databases/vendor/cc/sun/sparc/sunos/A.03.50/ packet.Z what(1) Output: /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/ncr/i386/mp-ras/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/gpl/i386/linux/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sco/i386/unixware/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sequent/i386/dynix/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sgi/mips/irix/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/siemens/r400/sinix/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sun/sparc/solaris/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sun/sparc/solaris-26/A.03.50/ packet.Z: None /opt/omni/databases/vendor/cc/sun/sparc/sunos/A.03.50/ packet.Z: None cksum(1) Output: 2415555503 11128717 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux-1020/A.03.50/packet.Z 2405709448 11166688 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux-10/A.03.50/packet.Z 1087481952 11139933 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux-11/A.03.50/packet.Z 3973517489 4171761 /opt/omni/databases/vendor/cc/ncr/i386/ mp-ras/A.03.50/packet.Z 2185661930 4927567 /opt/omni/databases/vendor/cc/dec/alpha/ osf1-4/A.03.50/packet.Z 3256413402 6829356 /opt/omni/databases/vendor/cc/gpl/i386/ linux/A.03.50/packet.Z 3795604029 4219274 /opt/omni/databases/vendor/cc/ibm/rs6000/ aix-42/A.03.50/packet.Z 3114785334 4023853 /opt/omni/databases/vendor/cc/sco/i386/ sco_sv/A.03.50/packet.Z 2212262710 3929673 /opt/omni/databases/vendor/cc/sco/i386/ unixware/A.03.50/packet.Z 1691238839 4127299 /opt/omni/databases/vendor/cc/sequent/ i386/dynix/A.03.50/packet.Z 1239372662 5016457 /opt/omni/databases/vendor/cc/sgi/mips/ irix/A.03.50/packet.Z 3200772212 5829171 /opt/omni/databases/vendor/cc/sgi/mips/ irix-62/A.03.50/packet.Z 1096359355 4877655 /opt/omni/databases/vendor/cc/siemens/ r400/sinix/A.03.50/packet.Z 1592991854 4579799 /opt/omni/databases/vendor/cc/sun/sparc/ solaris/A.03.50/packet.Z 478449338 4652147 /opt/omni/databases/vendor/cc/sun/sparc/ solaris-26/A.03.50/packet.Z 4283150974 6978031 /opt/omni/databases/vendor/cc/sun/sparc/ sunos/A.03.50/packet.Z Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_22038 PHSS_22850 Equivalent Patches: PHSS_24661: s700: 11.00 11.11 11.20 s800: 11.00 11.11 11.20 Patch Package Size: 95390 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_24660 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_24660.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_24660. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_24660.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_24660.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: PHSS_24660: NOTE! This Patch has to be installed on the Installation Server host. The User Interface must be redistributed to the client system(s) after the installation of the patch in order to get the fixes into effect. For distribution of the User Interface, refer to the OmniBackII Installation guide. NOTE! Fix for HSLco20414 introduces new options for device maintenance. The usage of new options is listed below: To disable/enable specific device and all other devices with the same lockname, run: omnimm -disable_device {device name} omnimm -enable_device {device name} To disable/enable all devices with the same lockname, run: omnimm -disable_lockname {lock name} omnimm -enable_lockname {lock name} To check if specific device is enabled/disabled, run: omnidownload -device {device name} To obtain complete functionality one has to install PHSS_24429/PHSS_24430 (CORE) and upcoming PHSS_24658/PHSS_24659 (Cell Server) or later patches as well. NOTE! Special instructions for JAGad35002: After the installation of the patch is finished and the Cell Console packet is redistributed, cluster related entries in cell_info file will disappear. In order to resolve this problem, please add the following additional keywords to the cell_info file: - "-clus "virtual.domain.com"" to primary names and a virtual name - "-clust node" to primary names - "-clust integvs" to a virtual name Example of cell_info file: -host "physical_1.domain.com" -clus "virtual.domain.comi"\ -clust node -os "hp s800 hp-ux-11.00" -cc A.03.50 \ -da A.03.50 -ma A.03.50 -host "physical_2.domain.com" -clus "virtual.domain.comi"\ -clust node -os "hp s800 hp-ux-11.00" -cc A.03.50 \ -da A.03.50 -ma A.03.50 -host "virtual.domain.com" -clus "virtual.domain.comi"\ -clust integvs -os "hp s800 hp-ux-11.00" -cc A.03.50 \ -da A.03.50 -ma A.03.50 Patch includes the following Site Specific Patches: SSPUX350_013 SSPUX350_020 SSPUX350_031 SSPUX350_038