Patch Name: PHSS_23819 Patch Description: s700_800 10.20 OV ITO6.0X HP-UX 10.x Agent Patch A.06.05 Creation Date: 01/04/05 Post Date: 01/04/10 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OpenView IT/Operations 6.0 Filesets: OVOPC-CLT.OVOPC-UX10-CLT,A.06.00 Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_23819 Symptoms: PHSS_23819: - The event correlation process opceca (agent) / opcecm (server) might crash after processing several annotation nodes - The VPO A.06.03 patches for HP-UX and Solaris do not work as expected in firewall environments: While server port restrictions are still regarded, client-side port restrictions are ignored. PHSS_22879: - Changes were required for the security add-on product VantagePoint Advanced Security. - agent installation configure script fails to convert ITO 4 queue files: awk syntax error in swagent.log file PHSS_22010: - disk_mon.sh returns invalid values if the bdf command returns more than one line output for a filesystem (e.g. if the filesystem name exceeds its column width) - Several changes for firewall environments. For detailed information refer to the VPO Firewall Configuration White Paper version 3.0 - When executing large numbers of autoactions, some of them were staying in 'running' state. - opctrapi aborts after getting traps with unresolvable IP address. - The handling of '\' was different in the pattern definition and the "matching pattern". - if buffer file size limitation is enabled the agent may discard low-severity messages even if there is still space in the buffer file Defect Description: PHSS_23819: check the list of the symptoms PHSS_22879: check the list of the symptoms PHSS_22010: check the list of the symptoms SR: B555010079 B555009155 B555009152 B555008613 B555008314 B555007752 B555007709 B555007602 B555007426 B555006890 B555006267 8606137088 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/mondbfile.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ssp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/st_syslogd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/E10000Log.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ssp_config.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrclchk: HP OpenView VantagePoint A.06.05 (04/04/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrdschk: HP OpenView VantagePoint A.06.05 (04/04/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrndchk: HP OpenView VantagePoint A.06.05 (04/04/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcroschk: HP OpenView VantagePoint A.06.05 (04/04/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrverchk: HP OpenView VantagePoint A.06.05 (04/04/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/install/opcrinst: HP OpenView VantagePoint A.06.05 (04/04/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/mondbfile.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ssp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/st_syslogd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/E10000Log.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ssp_config.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.05/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform: None cksum(1) Output: 2509331765 7534269 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/opc_pkg.Z 503497181 6898 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/install/ opcrclchk 254044229 28659 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/install/ opcrdschk 4105370163 6734 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/install/ opcrndchk 1502493738 6287 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/install/ opcroschk 646043549 32236 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/install/ opcrverchk 1001471436 105784 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/install/ opcrinst 3236819379 2728 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 3723284564 5974 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 3039701740 6130 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 3912100531 5845 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ last_logs.sh.Z 3088270956 5836 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 826800232 6006 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 1621453335 5876 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 3919631270 5434 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 1206224157 5733 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 295455397 6123 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 1294508585 14367 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ mondbfile.sh.Z 1799894926 5977 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ ssp_chk.sh.Z 3209935572 12414 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ opcfwtmp.Z 4125260283 9453 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ opcnprcs.Z 1515860928 17954 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z 447043091 2534 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/actions/ mailq_pr.sh.Z 3477892069 2578 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/actions/ st_inetd.sh.Z 361485162 2587 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/actions/ st_syslogd.sh.Z 456581874 2579 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/actions/ st_mail.sh.Z 2674152842 6109 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/actions/ dist_del.sh.Z 2897091675 324 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ opcdf.Z 3208669463 385 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ opclpst.Z 2975064225 400 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ opcps.Z 3924562579 3319 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ E10000Log.sh.Z 1151706234 3107 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ ssp_config.sh.Z 406356461 13165 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.05/RPC_DCE_TCP/cmds/ opc_sec_v.sh.Z 4181027508 6319 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/AgentPlatform 1179352839 6317 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux10/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_22010 PHSS_22879 Equivalent Patches: ITOSOL_00087: sparcSOL: 2.6 2.7 2.8 PHSS_23820: s700: 11.00 s800: 11.00 Patch Package Size: 7830 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_23819 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_23819.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_23819. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_23819.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_23819.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o It provides bug fixes and enhancements for the VPO A.06.00 Management Server system. o DO NOT use this patch with older releases of ITO, for example versions A.05.00, A.05.11 or A.05.30 (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. For backing up the system before installing a patch, you may use opc_backup(1m) NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the VPO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. Don't be afraid of the '-x autoreboot=true' option above. There won't be a reboot due to this VPO patch. You can skip this option if you like. NOTE: This patch must be installed on the VPO Management Server system, NOT on an VPO Managed Node directly. Changes will take effect on managed nodes by means of VPO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the VPO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_23819 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_23819