Patch Name: PHSS_22736 Patch Description: s700_800 10.20 OV ITO5.3X HP-UX 10.x Agent Patch A.05.37 Creation Date: 00/12/14 Post Date: 00/12/21 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OpenView IT/Operations 5.3 Filesets: OVOPC-CLT.OVOPC-UX10-CLT,A.05.30 Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_22736 Symptoms: PHSS_22736: - ITO Variable $MSG_ID not properly passed by ITO Message Text Interface - The command "opcagt -kill" sometimes doesn't kill all agent processes, mostly only opcctla is killed. - The IT/O Agent API call opcagtmsg_send() might leak memory if the opcmsgi isn't running. - The IT/O Agent API call opcagtmsg_send() might leak memory - The opctrapi might abort with OpC30-104 - ITO Agent might hang during ITA synchronisation when transferring bigger files (>0. 5 MB) from several nodes to the ITO server at the same time - In case of an error the ITO Agent might hang during startup without terminating - opctrapi might abort after getting traps with unresolvable IP address. - Use ECS runtime of ECS patches PHSS_22047, PHSS_22048 or PSOV_02769 to get the fixes of the patches. - Event correlation engine creates "Time cannot go backwards" error if the system is very busy. - When processes received synchronous signals (such as SIGABRT, SIGSEGV, SIGBUS), they sometimes looped at 100% CPU instead of writing a core file. PHSS_22004: - filtering ITO internal messages (OPC_INT_MSG_FLT TRUE in the opcinfo file) causes agent aborts if tracing is switched on. - installation check for running DCE processes matches all processes ending with 'rpcd' - swap_util monitor reports more swap space than you actually have because it does 'swapinfo -dft' instead of the more appropriate 'swapinfo -dftr' - agent installation has problems once the opcinfo file happens to be empty by accident - The opcfwtmp tool does not always report bad logins. - Setting up a logfile template that uses a dynamic path definition, like: <`echo "/tmp/path with spaces/logfile1.txt"`> This path will be handled as three logfiles: - /tmp/path - with - spaces/logfile1.txt - RPC template distribution fails if too many ( > ~70) templates are distributed. - In NAT environments the distribution does not work when an IP address is set for the system that does not physically exists on any of its network cards. PHSS_18454: - Pattern matching does not work correct on a Japanese system. - The trap interceptor opctrapi does not correctly handle the reconfig signal. - The trap interceptor opctrapi tries name resolution on segment names. - The trap interceptor opctrapi dies on some large traps. Defect Description: PHSS_22736: check the list of the symptoms PHSS_22004: check the list of the symptoms PHSS_18454: - Pattern matching does not work correct on a Japanese system. - The trap interceptor opctrapi does not correctly handle the reconfig signal. - The trap interceptor opctrapi tries name resolution on segment names. - The trap interceptor opctrapi dies on some large traps. Resolution: - Fixed bug in the multi byte character set handling. - Check for reconfig each time a trap comes in. - No name resolution is performed on segment names. They are handled as if name service returned not resolvable. - Increased buffer size for trap formatting. SR: R555004827 R555004825 R555001968 H555003505 H555003466 H555002653 H555002616 H555002499 H555002486 H555002486 B555008923 B555008838 B555008660 B555008314 B555007898 B555007439 B555007233 B555007187 B555006381 B555006098 B555006078 8606153194 8606141434 8606113695 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/mondbfile.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/itogpm.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrclchk: HP OpenView IT/Operations A.05.37 (12/04/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrdschk: HP OpenView IT/Operations A.05.37 (12/04/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrndchk: HP OpenView IT/Operations A.05.37 (12/04/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcroschk: HP OpenView IT/Operations A.05.37 (12/04/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrverchk: HP OpenView IT/Operations A.05.37 (12/04/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/install/opcrinst: HP OpenView IT/Operations A.05.37 (12/04/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/mondbfile.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/actions/itogpm.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.37/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform: None cksum(1) Output: 930230567 7082267 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/opc_pkg.Z 4221640752 6909 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/install/ opcrclchk 985937401 28403 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/install/ opcrdschk 1334830903 6681 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/install/ opcrndchk 1294462265 6300 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/install/ opcroschk 9898361 31976 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/install/ opcrverchk 382246625 109659 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/install/ opcrinst 2822436901 2566 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 3910437160 5951 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 3255625446 6039 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 3763371821 5829 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ last_logs.sh.Z 1641089574 5818 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 2883945097 3163 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ perf_alxp.sh.Z 2919454908 5990 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 42280488 5415 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 484685728 5907 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 209963920 5658 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 3453362758 5849 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ mwa_read.sh.Z 2602611739 6096 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 2955083677 14092 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ mondbfile.sh.Z 1210805551 10364 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ opcfwtmp.Z 1656005251 8897 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/monitor/ opcnprcs.Z 1827579115 2527 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/actions/ mailq_pr.sh.Z 3943091647 2567 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/actions/ st_inetd.sh.Z 512257150 2581 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/actions/ st_mail.sh.Z 4194170544 5762 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/actions/ pv.sh.Z 1955329689 6086 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/actions/ dist_del.sh.Z 3183489481 1374 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/actions/ itogpm.sh.Z 207567707 323 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/cmds/ opcdf.Z 3228716086 385 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/cmds/ opclpst.Z 1723124371 399 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/cmds/ opcps.Z 3440971844 13172 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.37/RPC_DCE_TCP/cmds/ opc_sec_v.sh.Z 3330858782 6312 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/AgentPlatform 3861268441 6310 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux10/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_18454 PHSS_22004 Equivalent Patches: PHSS_22737: s700: 11.00 s800: 11.00 ITOSOL_00063: sparcSOL: 2.3 2.4 2.5 2.6 2.7 Patch Package Size: 7370 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_22736 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_22736.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_22736. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_22736.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_22736.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO release: A.05.30 o DO NOT use this patch with older releases of ITO, for example versions A.05.00 or A.05.11. o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO A.05.30 Management Server system. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. ------------------------------------------------------ NOTE: For backing up the system before installing a patch, you may use opc_backup(1m). NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. NOTE: Don't be afraid of the '-x autoreboot=true' option above. There won't be a reboot due to this ITO patch. You can skip this option if you like. NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_22736 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_22736