Patch Name: PHSS_22012 Patch Description: s700_800 10.20 OV ITO6.0X HP-UX 11.x Agent Patch A.06.01 Creation Date: 00/10/18 Post Date: 00/10/24 Repost: 01/04/05 Superseding patch PHSS_22881 introduces behavior that can cause communication failures in firewall environments for VPO's communications that need to go through the firewall. This is the result of source (client) port restrictions being ignored. Observe that destination (server) port restrictions are correctly handled. PHSS_22012 does not exhibit this same problem and is being re-released until replacement patch PHSS_23821 becomes available. PHSS_23821 is expected to be released by April 13, 2001. Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OpenView IT/Operations 6.0 Filesets: OVOPC-CLT.OVOPC-UX11-CLT Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_22012 Symptoms: PHSS_22012: - disk_mon.sh returns invalid values if the bdf command returns more than one line output for a filesystem (e.g. if the filesystem name exceeds its column width) - Several changes for firewall environments. For detailed information refer to the VPO Firewall Configuration White Paper version 3.0 - When executing large numbers of autoactions, some of them were staying in 'running' state. - opctrapi aborts after getting traps with unresolvable IP address. - The handling of '\' was different in the pattern definition and the "matching pattern". - if buffer file size limitation is enabled the agent may discard low-severity messages even if there is still space in the buffer file Defect Description: PHSS_22012: check the list of the symptoms Resolution: check the list of the symptoms SR: B555008314 B555007752 B555007709 B555007602 B555007426 B555006890 B555006267 8606137088 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/mondbfile.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/ssp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/st_syslogd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/E10000Log.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ssp_config.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/AgentPlatform what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrclchk: HP OpenView VantagePoint A.06.01 (09/11/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrdschk: HP OpenView VantagePoint A.06.01 (09/11/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrndchk: HP OpenView VantagePoint A.06.01 (09/11/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcroschk: HP OpenView VantagePoint A.06.01 (09/11/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrverchk: HP OpenView VantagePoint A.06.01 (09/11/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/install/opcrinst: HP OpenView VantagePoint A.06.01 (09/11/00) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/mondbfile.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/ssp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/st_syslogd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/E10000Log.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ssp_config.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/A.06.01/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/pa-risc/ hp-ux11/AgentPlatform: None cksum(1) Output: 3770975336 7456873 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ opc_pkg.Z 3810141021 6708 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ install/opcrclchk 2896194149 28659 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ install/opcrdschk 2206007067 6720 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ install/opcrndchk 2504822429 6287 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ install/opcroschk 1629029149 31788 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ install/opcrverchk 3519981896 110064 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ install/opcrinst 4116039931 2726 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/ana_disk.sh.Z 1508957009 5983 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/cpu_mon.sh.Z 775017021 6068 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/disk_mon.sh.Z 2944991759 5863 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/last_logs.sh.Z 4037043241 5829 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/mailq_l.sh.Z 3954571249 6009 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/proc_mon.sh.Z 684893100 5428 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/sh_procs.sh.Z 3199316585 5901 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/swap_mon.sh.Z 1848104861 5736 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/vp_chk.sh.Z 450064332 6122 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/dist_mon.sh.Z 520920057 14342 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/mondbfile.sh.Z 2779387275 5980 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/ssp_chk.sh.Z 1870916938 13292 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/opcfwtmp.Z 1903893438 10108 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/opcnprcs.Z 105424142 18483 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ monitor/opc_get_ems_resource.Z 936552128 2536 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ actions/mailq_pr.sh.Z 4019850988 2573 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ actions/st_inetd.sh.Z 3482188530 2584 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ actions/st_syslogd.sh.Z 3779140364 2579 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ actions/st_mail.sh.Z 3541623325 6097 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/ actions/dist_del.sh.Z 1971378774 325 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ opcdf.Z 2458393582 386 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ opclpst.Z 2490361302 401 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ opcps.Z 3086126559 3319 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ E10000Log.sh.Z 4054984815 3109 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ ssp_config.sh.Z 547584099 13201 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/A.06.01/RPC_DCE_TCP/cmds/ opc_sec_v.sh.Z 3300312464 6324 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/pa-risc/hp-ux11/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_22013: s700: 11.00 11.10 s800: 11.00 11.10 ITOSOL_00042: sparcSOL: 2.3 2.4 2.5 2.6 2.7 Patch Package Size: 7750 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_22012 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_22012.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_22012. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_22012.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_22012.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official VPO releases: A.06.0x o DO NOT use this patch with older releases of ITO, for example versions A.05.00, A.05.11 or A.05.30 o This patch provides the HP OV VPO Intelligent Agent to be used with a VPO 6.0x Management Server system, English and Japanese version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_22012 4. For a standalone system, run swinstall to install the patch: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. # swinstall -x match_target=true \ -s /tmp/PHSS_22012.depot It is recommended that you move the PHSS_22012.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_22012.depot of=/dev/rmt/0m bs=2k NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_22012 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_22012