Patch Name: PHSS_21734 Patch Description: s700_800 10.X OV OB3.10 patch - SSEA packet Creation Date: 00/06/06 Post Date: 00/07/06 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.03.10 Filesets: OMNIBACK-II.OMNI-CORE-IS Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_21734 Symptoms: PHSS_21734: Id = NSMex03058 Raw disk backup on SSE XP256 BC/1 Configuration fails with the error message: "Internal error: Unknown option -bc1". PHSS_19525: Id = HSLco16368 HP SureStoreE Disk Array XP256 is not supported by OmniBack II to perform a split mirror backup. This patch does not fix any other problem. Defect Description: PHSS_21734: Id = NSMex03058 The option '-bc1' is not recognized by the SSEA agent. Resolution: The SSEA agent has been improved to recognize the '-bc1' option, which results in starting a backup of disk pairs. PHSS_19525: Id = HSLco16368 Currently OmniBack II only supports the Split Mirror Backup concept with EMC Symmetrix. After the introduction of the new HP SureStoreE Disk Array XP256, it was requested that OmniBack II also supports this disk array with the split mirror backup concept. This requires to support Oracle 8.0.x and SAP R/3 in this concept as well. In addition a new manual is needed. Resolution: The SureStoreE Agent (SSEA) was developed for HP-UX to control the SureStoreE disk array. The Backup Session Manager, INET on HP-UX, and the NT GUI were enhanced and in addition Oracle 8.0.x and SAP integrations are supported. Also the manual "HP OpenView OmniBack II HP SureStore E Disk Array XP256 Configuration Guide" will be released. SR: 0000000000 Patch Files: /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.10/ packet.Z /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.10/ require.dat what(1) Output: /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.10/ packet.Z: None /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.10/ require.dat: None cksum(1) Output: 3002982931 480793 /opt/omni/databases/vendor/ssea/hp/s800/ hp-ux-1020/A.03.10/packet.Z 2484855657 23 /opt/omni/databases/vendor/ssea/hp/s800/ hp-ux-1020/A.03.10/require.dat Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_19525 Equivalent Patches: PHSS_21735: s700: 11.00 s800: 11.00 Patch Package Size: 530 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_21734 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_21734.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_21734. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_21734.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_21734.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: PHSS_21734: NOTE! This patch fixes a problem on systems with HP SureStore E Disk Array XP 256 integration. If this functionality is not required, the patch should not be installed. NOTE! This patch must be installed on the Installation Server host. The patch PHSS_19525 introduced new client SSEA that is only visible in the Windows NT "Install" user interface. In order to support the SureStoreE Agent changes this agent must be installed on the appropriate systems. Refer to the "HP OpenView OmniBack II HP SureStore E Disk Array XP 256 Configuration Guide" for more details on the installation. NOTE! Only the OmniBackII graphical user interface on Windows NT supports the installation of the SSEA. In order to enable the HP SurStoreE Agent (SSEA) functionality, a license-to-use (B7023AA) must be installed. In addition, at least the following OB2 patches are required: PHSS_21650/PHSS_21651 - Cell Server patch PHSS_20111/PHSS_20112 - Oracle8 integration patch PHSS_21770/PHSS_21771 - Core patch PHSS_21732/PHSS_21733 - SAP integration patch OMNIBACK_00012 - Windows NT Some of these above mentioned patches may be superseded by a newer patch. Please check the HP Electronic Support Center web page for latest and the most up to date patch status. For more information regarding the installation procedure refer to the "HP OpenView OmniBack II HP SureStore E Disk Array XP256 Configuration Guide" Patch includes the following Site Specific Patches: SSPUX310_012