Patch Name: PHSS_19469 Patch Description: s700_800 10.X OV ITO4.0X HP-UX 11.x Agt Patch A.04.16 Creation Date: 99/08/16 Post Date: 99/08/25 Hardware Platforms - OS Releases: s700: 10.01 10.10 10.20 s800: 10.01 10.10 10.20 Products: OpenView IT/Operations 4.0 Filesets: OVOPC-CLT.OVOPC-UX11-CLT Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_19469 Symptoms: PHSS_19469: - fixed various Problems with ITO Schedule templates/actions - if the time gets set backwards no monitors are executed until the inital time is reached again. - in automatic actions some multibyte strings were truncated. - opcagt sometimes does not start after system boot, if rpcd is not completely initialized. PHSS_17911: - Fix permission problem during Agent installation. PHSS_17682: - The PHSS_17501 ITO HP-UX 11 agent patch causes HP OpenView IT/Aadministration agents and potentially also other integrated applications to abort. This is because the PHSS_17501 software was built on HP-UX 11 and thus causes 'unpredictable behaviour' of applications linked on HP-UX 10. You don't need PHSS_17682 if you don't have ITA or other integrated applications running with ITO agents. PHSS_17501: - The HP-UX 11 agent was linked against DCE 1.7 libraries. This caused an abort for applications using the ITO API/MSI which were linked on HP-UX 10 with the older DCE 1.5 (message: "unresolved symbols from libcma.2") This patch contains ITO libs (libopc_r.sl and libnsp.sl) which are linked with the DCE 1.5 version. PHSS_17356: - after a failed subagent installation transfer the next try has a problem because a leftover temporary file could not be overwritten - trap interceptor may generate OpC30-204 during system reboot because the ITO agent is shut down after pmd. This is due to a wrong naming of the /sbin/rc2.d/*opcagt startup scripts: should be three digits - leading '0' missing - opcmsg(3) behaves inconsistently if agent is not running: sometimes it queues the message instead of discarding it as the return code OPC_ERR_NO_AGENT suggests. - agent refuses to start after manual installation because default communication type setting was not set by the opcactivate script - opcmon '-object' and '-option' options and 'duration' in conditions do not work together - opcacta aborts when opctranm is used with certain jobfile settings - memory leaks in trap interceptor - OPC_TRACE_TRUNC FALSE for suppressed messages does not work - Error during subagent installation transfer (OpC40-745) due to short/long hostname checking problems PHSS_15675: - The <$MSG_ID> variable is not set correctly in monitor conditions. - Agent reinstallation does not work from remote SD depot. - Scheduled actions are scheduled for the following month if weekday is specified. - Deinstallation of agent leaves files on system but no SD error messages. - Usage of the opcmsg() API may cause the application to abort. - Message agent sometimes stays in the buffering state forever. - The opcfwtmp command returns UTC time instead of local time. - The logfile encapsulator might coredump when tracing is turned on and very long messages are generated. - The logfile encapsulator suddenly starts growing to the kernel limit and coredumps. PHSS_13550: - changed hp/s700/hp-ux11 platform number PHSS_13027: - Adds support for HP-UX 11.00 for IT/Operations 4.0X Defect Description: PHSS_19469: check the list of the symptoms Resolution: check the list of the symptoms PHSS_17911: check the list of the symptoms Resolution: check the list of the symptoms PHSS_17682: check the list of the symptoms PHSS_17501: check the list of the symptoms PHSS_17356: check the list of the symptoms PHSS_15675: check the list of the symptoms PHSS_13550: check the list of the symptoms PHSS_13027: check the list of the symptoms SR: 1653276568 1653272344 5003396960 1653259317 5003461095 5003462192 1653296830 Patch Files: /opt/OV/OpC/examples/progs/Makef.hpux11 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/mondbfile.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/itogpm.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux11/AgentPlatform what(1) Output: /opt/OV/OpC/examples/progs/Makef.hpux11: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrclchk: HP OpenView IT/Operations A.04.16 (08/16/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrdschk: HP OpenView IT/Operations A.04.16 (08/16/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrndchk: HP OpenView IT/Operations A.04.16 (08/16/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcroschk: HP OpenView IT/Operations A.04.16 (08/16/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrverchk: HP OpenView IT/Operations A.04.16 (08/16/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/install/opcrinst: HP OpenView IT/Operations A.04.16 (08/16/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/mondbfile.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/actions/itogpm.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.16/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux11/AgentPlatform: None cksum(1) Output: 834793237 833 /opt/OV/OpC/examples/progs/Makef.hpux11 243020216 2917775 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/opc_pkg.Z 4153476549 6892 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/install/ opcrclchk 2485501797 28084 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/install/ opcrdschk 3978929649 6662 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/install/ opcrndchk 1996416454 6295 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/install/ opcroschk 871549842 31495 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/install/ opcrverchk 1330971546 97698 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/install/ opcrinst 2638846228 2554 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 2077816180 5883 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 4285083014 5896 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 4141646334 5787 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ last_logs.sh.Z 3155390736 5728 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 3498812151 3152 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ perf_alxp.sh.Z 749681383 5899 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 327261210 5341 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 1114902600 5811 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 3252358653 5587 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 2392825098 5769 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ mwa_read.sh.Z 3541335274 6026 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 3068874777 12948 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ mondbfile.sh.Z 3689673357 9409 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ opcfwtmp.Z 944792187 8557 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/monitor/ opcnprcs.Z 2522422694 2528 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/actions/ mailq_pr.sh.Z 1899253479 2548 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/actions/ st_inetd.sh.Z 2717573203 2558 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/actions/ st_mail.sh.Z 4252547768 5691 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/actions/ pv.sh.Z 996351514 5988 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/actions/ dist_del.sh.Z 4116386596 1373 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/actions/ itogpm.sh.Z 4237794441 320 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/cmds/ opcdf.Z 3299876255 333 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/cmds/ opclpst.Z 2410342581 359 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/cmds/ opcps.Z 3528928931 13068 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.16/RPC_DCE_TCP/cmds/ opc_sec_v.sh.Z 2547749933 4896 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/AgentPlatform 2566711868 4894 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux11/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_13027 PHSS_13550 PHSS_15675 PHSS_17356 PHSS_17501 PHSS_17682 PHSS_17911 Equivalent Patches: None Patch Package Size: 3290 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_19469 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_19469.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_19469. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_19469.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_19469.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO releases: A.04.0x o DO NOT use this patch with older releases of OpC or ITO, for example versions A.01.X, A.02.X or A.03.X. or with newer releases like A.05.X o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO 4.0x Management Server system, English and Japanese version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_19469 4. For a standalone system, run swinstall to install the patch: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. # swinstall -x match_target=true \ -s /tmp/PHSS_19469.depot It is recommended that you move the PHSS_19469.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_19469.depot of=/dev/rmt/0m bs=2k NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. NOTE: This patch patches the OVOPC-CLT.OVOPC-UX11-CLT fileset which was not available during original ITO A.04.00 release but introduced later with PHSS_13550. If you don't have PHSS_13550 or a superseding patch installed, this patch will now add the OVOPC-CLT.OVOPC-UX11-CLT to your system and update the ITO database accordingly. After installing this patch, please restart the ITO Administrator user interface processes on your Management Server system to make this new agent platform available to the GUI. If you're applying this patch to an ITO Server running on an HP-UX 11 which has the mentioned OVOPC-CLT.OVOPC-UX11-CLT fileset already installed, please swinstall this patch with the additional '-x enforce_dependencies=false' to skip the installation of OVOPC-CLT.OVOPC-UX11-CLT. o There are no additional default message source templates available for HP-UX 11.0. Use the ITO default templates for HP-UX 10.x. o Installation prerequisites for the ITO HP-UX 11.0 software are the same as for the ITO HP-UX 10.x agents. See Chapter 1 of the HP OV ITO Administrator's Reference for information about managed node prerequisites, and Chapter 2 for installation tips. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_19469 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_19469 NOTE: If you installed this patch on an ITO system which didn't have the HP-UX 11 agent support before, the OVOPC-UX11-CLT fileset has been installed together with this patch. To get rid of the HP-UX 11 support, you have to swremove this fileset together with this patch: # swremove PHSS_19469 OVOPC-CLT.OVOPC-UX11-CLT