Patch Name: PHSS_18454 Patch Description: s700_800 10.X OV ITO5.3X HP-UX 10.x Agent Patch A.05.31 Creation Date: 99/11/12 Post Date: 99/11/16 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OpenView IT/Operations 5.30 Filesets: OVOPC-CLT.OVOPC-UX10-CLT Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_18454 Symptoms: PHSS_18454: - Pattern matching does not work correct on a Japanese system. - The trap interceptor opctrapi does not correctly handle the reconfig signal. - The trap interceptor opctrapi tries name resolution on segment names. - The trap interceptor opctrapi dies on some large traps. Defect Description: PHSS_18454: - Pattern matching does not work correct on a Japanese system. - The trap interceptor opctrapi does not correctly handle the reconfig signal. - The trap interceptor opctrapi tries name resolution on segment names. - The trap interceptor opctrapi dies on some large traps. Resolution: - Fixed bug in the multi byte character set handling. - Check for reconfig each time a trap comes in. - No name resolution is performed on segment names. They are handled as if name service returned not resolvable. - Increased buffer size for trap formatting. SR: R555001968 R555004827 R555004825 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/mondbfile.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/itogpm.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrclchk: HP OpenView IT/Operations A.05.31 (10/26/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrdschk: HP OpenView IT/Operations A.05.31 (10/26/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrndchk: HP OpenView IT/Operations A.05.31 (10/26/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcroschk: HP OpenView IT/Operations A.05.31 (10/26/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrverchk: HP OpenView IT/Operations A.05.31 (10/26/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/install/opcrinst: HP OpenView IT/Operations A.05.31 (10/26/99) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/mondbfile.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/actions/itogpm.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.05.31/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform: None cksum(1) Output: 1827008211 4236179 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/opc_pkg.Z 2484622845 6909 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/install/ opcrclchk 450379968 28403 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/install/ opcrdschk 1803693343 6681 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/install/ opcrndchk 3695826289 6300 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/install/ opcroschk 2798800278 31976 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/install/ opcrverchk 788175318 109996 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/install/ opcrinst 3239877023 2554 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 90378768 5956 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 2780194020 6039 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 293325801 5834 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ last_logs.sh.Z 2963051380 5814 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 4106325569 3154 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ perf_alxp.sh.Z 3984512738 5974 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 1214209633 5428 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 3788755936 5897 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 3081956811 5639 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 1755669475 5829 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ mwa_read.sh.Z 2790919223 6107 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 1969991109 14150 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ mondbfile.sh.Z 447877432 9851 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ opcfwtmp.Z 632328850 8710 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/monitor/ opcnprcs.Z 3476881548 2530 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/actions/ mailq_pr.sh.Z 3764059694 2570 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/actions/ st_inetd.sh.Z 1691728292 2584 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/actions/ st_mail.sh.Z 1763194383 5754 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/actions/ pv.sh.Z 3122329580 6074 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/actions/ dist_del.sh.Z 3884018703 1374 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/actions/ itogpm.sh.Z 381496166 321 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/cmds/ opcdf.Z 3683694959 384 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/cmds/ opclpst.Z 3763133710 398 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/cmds/ opcps.Z 632284244 13187 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.05.31/RPC_DCE_TCP/cmds/ opc_sec_v.sh.Z 3717789549 6312 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/AgentPlatform 4248203178 6310 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux10/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_18455: s700: 11.00 s800: 11.00 Patch Package Size: 4580 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_18454 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_18454.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_18454. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_18454.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_18454.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO release: A.05.30 o DO NOT use this patch with older releases of ITO, for example versions A.05.00 or A.05.11. o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO A.05.30 Management Server system, English and Japanese version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. ------------------------------------------------------ NOTE: For backing up the system before installing a patch, you may use opc_backup(1m). NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. NOTE: Don't be afraid of the '-x autoreboot=true' option above. There won't be a reboot due to this ITO patch. You can skip this option if you like. NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_18454 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_18454