Patch Name: PHSS_17914 Patch Description: s700_800 10.X OV ITO4.0X MPE Agt Patch A.04.16 Creation Date: 99/10/27 Post Date: 99/11/01 Hardware Platforms - OS Releases: s700: 10.01 10.10 10.20 s800: 10.01 10.10 10.20 Products: OpenView IT/Operations 4.0 Filesets: OVOPC-CLT-ENG.OVOPC-MPE-CLT Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_17914 Symptoms: PHSS_17914: - fixed various Problems with ITO Schedule templates/actions - if the time gets set backwards no monitors are executed until the inital time is reached again. PHSS_17366: - Add support for MPE 6.0 PHSS_14182: - The monitor agent queue got corrupted. - The monitor agent endlessly sent critical messages in a loop. - Corrupted queue files have not been repaired automatically. - The message agent aborted in some MoM configurations Defect Description: PHSS_17914: check the list of the symptoms PHSS_17366: The ITO MPE agent requires NCS on MPE. Therefore it is required to install the following MPE/iX 6.0 NCS patch: ITOED07A before installing this new agent on the MPE node. PHSS_14182: check the list of the symptoms SR: 1653173708 1653270447 1653276568 1653286930 1653287409 5003461095 5003462192 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/arcx /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcchka /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcchks /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcchkt /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcstart /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/setfcode /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/sysstrtj /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_login /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_opcchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_opcinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_opcstart what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/arcx: HP31508A A.01.01 HP SYMBOLIC DEBUGGER (XDBEND.PU B.SYS) $Revision: 68.6 $ 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcchka: HP30315 A.05.10 95/02/08 NRT0 Startup routine gethost: A0006000 $ NCS/NCK 1.5.1 $ 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcchks: HP30315 A.05.10 95/02/08 NRT0 Startup routine gethost: A0006000 $ NCS/NCK 1.5.1 $ 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcchkt: HP30315 A.05.10 95/02/08 NRT0 Startup routine 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/opcstart: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/setfcode: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/sysstrtj: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_login: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_opcchk: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_opcinst: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.04.16/RPC_NCS/vt3k_opcstart: None cksum(1) Output: 2921595073 3967 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/AgentPlatform 3544571954 431104 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/arcx 1887355259 128 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/cmds/opcdf.Z 2463369164 135 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/cmds/opclpst.Z 1160247176 137 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/cmds/opcps.Z 1133339567 10446592 /var/opt/OV/share/databases/OpC/ mgd_node/vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/ opc_pkg.Z 4110669334 558336 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/opcchka 390709094 553728 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/opcchks 2663517756 40448 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/opcchkt 335737184 616 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/opcstart 1778489180 5277 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/setfcode 356313829 855 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/sysstrtj 4049887895 765 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/vt3k_login 3670070797 10021 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/vt3k_opcchk 2403901884 4607 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/vt3k_opcinst 1017327619 1908 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.04.16/RPC_NCS/vt3k_opcstart Patch Conflicts: None Patch Dependencies: s700: 10.01 10.10 10.20: PHSS_17365 s800: 10.01 10.10 10.20: PHSS_17365 Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_14182 PHSS_17366 Equivalent Patches: None Patch Package Size: 11870 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_17914 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_17914.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_17914. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_17914.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_17914.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO releases: A.04.0x o DO NOT use this patch with older releases of OpC or ITO, for example versions A.01.X, A.02.X or A.03.X. or with newer releases like A.05.X o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO 4.0x Management Server system, English and Japanese version. Required MPE/iX Patches ....................... o MPE Patch ITOED07A must be installed on all MPE/iX 6.0 systems. This patch provides routines to the XL.PUB.SYS to allow the the ITO agent to call various NCS routines. As of MPE Agent patch PHSS_17366 ITO 4.X supported the following versions: MPE 5.0 5.5 6.0 This patch (PHSS_17914) supports MPE 5.5 and 6.0 and removes support for MPE 5.0 since this OS version is not Y2K compliant. Therefore customers still using ITO with MPE 5.0 agents should NOT install this patch !! -------------------------------------------- (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_17914 4. For a standalone system, run swinstall to install the patch: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. # swinstall -x match_target=true \ -s /tmp/PHSS_17914.depot It is recommended that you move the PHSS_17914.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_17914.depot of=/dev/rmt/0m bs=2k NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_17914 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_17914