Patch Name: PHSS_17311 Patch Description: s700_800 10.X OV OB3.00 patch - DA packet Creation Date: 99/04/16 Post Date: 99/04/26 Warning: 99/05/24 - This Critical Warning has been issued by HP. - PHSS_17311 introduces a problem with raw disk backups from OmniBack A.03.00. The backups appear to complete successfully, but the data cannot be recovered during a restore. - The problem only affects the backup of raw disks. The problem does not affect the backup of file systems, Very Big File Systems, the OmniBack II database, SAP objects, Oracle objects, or Sybase objects with OmniBack A.03.00. - HP recommends that PHSS_17311 be removed from all systems that use OmniBack A.03.00 to backup raw disks. It should also be removed from all software depots that may be used to install patches on systems that use OmniBack A.03.00 to backup raw disks. Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.03.00 Filesets: OMNIBACK-II.OMNI-HPUX-P OMNIBACK-II.OMNI-OTHUX-P OMNIBACK-II.OMNI-OST-P Automatic Reboot?: No Status: General Superseded With Warnings Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_17311 Symptoms: PHSS_17311: Id = NSMbb21590 Restore of files with 16 ACLs fails. Id = NSMex01880 Directories restored with permission attributes 777 instead of as set at backup time. Id = NSMex01990 OmniStorage 3.0 integration reports lots of '/usr/lib/dld.sl: Unresolved symbol:' messages. Id = NSMex01919 After installing the OmniStorage patch PHSS_15818, OmniBack integration fails with the message: 'BRRead return value = 0' and fails for migrated files. Id = NSMex02051 Post Exec fails with exitcode 1. Id = HSLco13219 Omnistream reports warnings to both stdout and stderr. Id = HSLco12499 OmniBack II raw backup fails on Irix 6.x if the capacity of the raw device is bigger than 2GB. Defect Description: PHSS_17311: Id = NSMbb21590 The number of ACLs hardcoded to 15 causes OmniBackII not being able to restore files with 16 ACLs correctly. Resolution: The number of ACLs per file changed to 16. Id = NSMex01880 In some circumstances, the restore can change permission attributes of a directory to 777. This is not OK, since this enables anyone to access it. Resolution: Vrda now correctly sets the access permissions of files. Id = NSMex01990 The nvbda and nvrda executables are not linked with OmniStorage 3.0 libraries. This causes them to core dump. Part of SSPUX300_025. Resolution: OmniStorage integration binaries linked with OST 3.0 libraries. Id = NSMex01919 At the end of backup, nvbda tries to close an invalid file handle - functionality remained from older OmniStorage library versions, where every file had to be closed twice. Part of SSPUX300_026. Resolution: Change in the code, and relink with newest OST library. Id = NSMex02051 Problem occurs if PreExec or PostExec script forks, and parent process dies before child process. Part of SSPUX300_047. Resolution: Relation between dad and forked child improved. Id = HSLco13219 Omnistream duplicates the warning messages to stdout, although they have already been written to stderr. Part of SSPUX300_037. Resolution: Use correct filehandle (stderr) for warning messages. Id = HSLco12499 Ioctl function returns zero, when obtaining the raw disk size, if the disk is bigger than 2Gb on IRIX 6.x. Part of SSPUX300_053. Resolution: Disk agent now detects the disk size by seeking to the end of disk, using the binary search technique. SR: 1653281113 Patch Files: /opt/omni/databases/vendor/da/hp/s800/hp-ux/A.03.00/packet.Z /opt/omni/databases/vendor/da/hp/s800/hp-ux-10/A.03.00/ packet.Z /opt/omni/databases/vendor/da/hp/s800/hp-ux-1020/A.03.00/ packet.Z /opt/omni/databases/vendor/da/ibm/rs6000/aix/A.03.00/ packet.Z /opt/omni/databases/vendor/da/ibm/rs6000/aix-42/A.03.00/ packet.Z /opt/omni/databases/vendor/da/sun/sparc/solaris/A.03.00/ packet.Z /opt/omni/databases/vendor/da/sun/sparc/sunos/A.03.00/ packet.Z /opt/omni/databases/vendor/da/sgi/mips/irix/A.03.00/packet.Z /opt/omni/databases/vendor/da/sgi/mips/irix-62/A.03.00/ packet.Z /opt/omni/databases/vendor/da/dec/alpha/osf1-4/A.03.00/ packet.Z /opt/omni/databases/vendor/da/sco/i386/sco_sv/A.03.00/ packet.Z /opt/omni/databases/vendor/da/siemens/r400/sinix/A.03.00/ packet.Z /opt/omni/databases/vendor/ost/hp/s800/hp-ux/A.03.00/ packet.Z /opt/omni/databases/vendor/ost/hp/s800/hp-ux-10/A.03.00/ packet.Z what(1) Output: /opt/omni/databases/vendor/da/hp/s800/hp-ux/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/hp/s800/hp-ux-10/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/hp/s800/hp-ux-1020/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/ibm/rs6000/aix/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/ibm/rs6000/aix-42/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/sun/sparc/solaris/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/sun/sparc/sunos/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/sgi/mips/irix/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/sgi/mips/irix-62/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/dec/alpha/osf1-4/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/sco/i386/sco_sv/A.03.00/ packet.Z: None /opt/omni/databases/vendor/da/siemens/r400/sinix/A.03.00/ packet.Z: None /opt/omni/databases/vendor/ost/hp/s800/hp-ux/A.03.00/ packet.Z: None /opt/omni/databases/vendor/ost/hp/s800/hp-ux-10/A.03.00/ packet.Z: None cksum(1) Output: 1693930128 990337 /opt/omni/databases/vendor/da/hp/s800/ hp-ux/A.03.00/packet.Z 1905963684 1030472 /opt/omni/databases/vendor/da/hp/s800/ hp-ux-10/A.03.00/packet.Z 1006839466 1201280 /opt/omni/databases/vendor/da/hp/s800/ hp-ux-1020/A.03.00/packet.Z 351025661 575804 /opt/omni/databases/vendor/da/ibm/rs6000/ aix/A.03.00/packet.Z 4215958023 611127 /opt/omni/databases/vendor/da/ibm/rs6000/ aix-42/A.03.00/packet.Z 19082668 808805 /opt/omni/databases/vendor/da/sun/sparc/ solaris/A.03.00/packet.Z 2827028783 1543239 /opt/omni/databases/vendor/da/sun/sparc/ sunos/A.03.00/packet.Z 4137592585 903769 /opt/omni/databases/vendor/da/sgi/mips/ irix/A.03.00/packet.Z 3229034352 1178953 /opt/omni/databases/vendor/da/sgi/mips/ irix-62/A.03.00/packet.Z 722652255 906668 /opt/omni/databases/vendor/da/dec/alpha/ osf1-4/A.03.00/packet.Z 517608238 661715 /opt/omni/databases/vendor/da/sco/i386/ sco_sv/A.03.00/packet.Z 3737520908 1162835 /opt/omni/databases/vendor/da/siemens/ r400/sinix/A.03.00/packet.Z 1998851905 749287 /opt/omni/databases/vendor/ost/hp/s800/ hp-ux/A.03.00/packet.Z 3228601520 2547783 /opt/omni/databases/vendor/ost/hp/s800/ hp-ux-10/A.03.00/packet.Z Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_17312: s700: 11.00 s800: 11.00 Patch Package Size: 14600 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_17311 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_17311.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_17311.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_17311. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_17311.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_17311.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: PHSS_17311: NOTE! Patch has to be installed on the Installation Server host. The Disk Agent packets must be redistributed to the Cell Manager system and client systems afterwards to get the fixes into effect. NOTE! This patch introduces OmniStorage 3.0 integration. In order to get it configured, these steps should be taken after pushing the OmniStorage integration package to the client system (to preserve the old binaries and make 3.0 integration effective): # cd /opt/omni/lbin # mv nvbda nvbda.orig # mv nvrda nvbda.orig # cp nvbda_3.0 nvbda # cp nvrda_3.0 nvrda Patch includes the following Site Specific Patches: SSPUX300_025 SSPUX300_026 SSPUX300_037 SSPUX300_047 SSPUX300_053