Patch Name: PHSS_16715 Patch Description: s700_800 10.X OV OB3.00 patch - CORE packet Creation Date: 98/12/23 Post Date: 99/01/06 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.03.00 Filesets: OMNIBACK-II.OMNI-CORE-IS Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_16715 Symptoms: PHSS_16715: Id = HSLco11740 The disk Agent package can not be installed on IRIX 6.4. Defect Description: PHSS_16715: Id = HSLco11740 Installation of the Disk Agent on IRIX 6.4 not supported. Support will now be added. SR: 0000000000 Patch Files: /opt/omni/lbin/bmsetup /opt/omni/databases/vendor/omnicf/sgi/mips/irix-62/A.03.00/ packet.Z what(1) Output: /opt/omni/lbin/bmsetup: [TZ=GMT0 /opt/omni/lbin/bmsetup -version] HP OpenView OmniBack II A.03.00: BMSETUP, internal b uild 699, built on Fri Dec 11 13:17:40 1998 /opt/omni/databases/vendor/omnicf/sgi/mips/irix-62/A.03.00/ packet.Z: None cksum(1) Output: 150831353 411537 /opt/omni/lbin/bmsetup 1950066992 1204613 /opt/omni/databases/vendor/omnicf/sgi/ mips/irix-62/A.03.00/packet.Z Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_16716: s700: 11.00 s800: 11.00 Patch Package Size: 1630 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_16715 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_16715.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_16715.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_16715. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_16715.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_16715.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: NOTE! Patch has to be installed on all Installation server hosts.