Patch Name: PHSS_16124 Patch Description: s700_800 10.X OV OB2.10 Data Append corrective Patch Creation Date: 98/08/06 Post Date: 98/08/10 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.02.10 Filesets: OMNIBACK-II.OMNI-CS OMNIBACK-II.OMNI-DAS-P OMNIBACK-II.OMNI-ACS-P OMNIBACK-II.OMNI-MA-P Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_16124 Symptoms: PHSS_16124: Id = NSMex01597 Installation of MA packet on a Media Agent client on HP-UX 10.x failed with error: "An I/O error occurred while performing this task." PHSS_15869: Id = NSMex01284 Backup could overwrite part of the data during append. Id = NSMex01379 Backup Media Agent for direct access devices corrupted the data on the MO medium. Id = NSMex00995 Restore failed with "Can't access a file." Id = NSMex00715 Omnimm command failed on STK9710 with error "Cannot load exchanger medium (Error 0)". Id = NSMex01153 Backup of Magneto Optical device on HP-UX 9.x failed with an error: "Cannot open device (Invalid argument)" Id = NSMex01132 Backup of filesystem failed with an error: "Could not allocate media for the backup. Media management subsystem reports: "No media to allocate."." Defect Description: PHSS_16124: The installation failed because the MA packet was erro- neously in 9.x format. It was updated to the correct format for HP-UX 10.x. PHSS_15869: Id = NSMex01284 To append to a medium, omniback uses the seek function which is supposed to fail at the End Of Data. This function could fail for other reasons, causing the write operation to start from a wrong position on the tape and overwriting valid data. An additional check was added to prevent this. If the seek now fails, then the respective tape is marked as poor. It should then be verified with the 'omnimver' command. Id = NSMex01379 If the direct access medium (optical disks, disks, files) contained a great number of small backups (maximum 475), there was a possibility of corruption of the data. Number of the segments on the medium is now restricted to 950. Id = NSMex00995 Restore failed with "Can't access a file." the cause was the RSM coredumped due to Restore Disk Agent time out. Part of SSP_54. Id = NSMex00715 Omnimm command failed on STK9710 if "Fastloadenabled" on STK device was disabled. The problem was partially solved with PHSS_12865. Part of SSP_56. Id = NSMex01153 Backup of Magneto Optical device on HP-UX 9.x failed with an error: "Cannot open device (Invalid argument)" Part of SSP_57. Id = NSMex01132 Backup of filesystem failed with an error: "Could not allocate media for the backup. Media management subsystem reports: "No media to allocate."." Problem appeared if several backups were started, one shortly after the other. Part of SSP_60. SR: 5003419937 Patch Files: /opt/omni/databases/vendor/ma/hp/s800/hp-ux/A.02.10/packet.Z /opt/omni/databases/vendor/ma/hp/s800/hp-ux-10/A.02.10/ packet.Z /opt/omni/databases/vendor/ma/ibm/rs6000/aix/A.02.10/ packet.Z /opt/omni/databases/vendor/ma/sun/sparc/solaris/A.02.10/ packet.Z /opt/omni/databases/vendor/das/hp/s800/hp-ux/A.02.10/ packet.Z /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/A.02.10/ packet.Z /opt/omni/databases/vendor/acs/hp/s800/hp-ux/A.02.10/ packet.Z /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/A.02.10/ packet.Z /opt/omni/lbin/rsm /opt/omni/lbin/bsm what(1) Output: /opt/omni/databases/vendor/ma/hp/s800/hp-ux/A.02.10/ packet.Z: None /opt/omni/databases/vendor/ma/hp/s800/hp-ux-10/A.02.10/ packet.Z: None /opt/omni/databases/vendor/ma/ibm/rs6000/aix/A.02.10/ packet.Z: None /opt/omni/databases/vendor/ma/sun/sparc/solaris/A.02.10/ packet.Z: None /opt/omni/databases/vendor/das/hp/s800/hp-ux/A.02.10/ packet.Z: None /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/A.02.10/ packet.Z: None /opt/omni/databases/vendor/acs/hp/s800/hp-ux/A.02.10/ packet.Z: None /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/A.02.10/ packet.Z: None /opt/omni/lbin/rsm: [TZ=GMT0 /opt/omni/lbin/rsm -version] HP OpenView OmniBack II A.02.10: RSM, built on Mon J ul 13 12:28:49 1998 /opt/omni/lbin/bsm: [TZ=GMT0 /opt/omni/lbin/bsm -version] HP OpenView OmniBack II A.02.10: BSM, built on Mon J ul 13 12:28:22 1998 cksum(1) Output: 4185134091 1274667 /opt/omni/databases/vendor/ma/hp/s800/ hp-ux/A.02.10/packet.Z 234181731 1419063 /opt/omni/databases/vendor/ma/hp/s800/ hp-ux-10/A.02.10/packet.Z 2645671411 1147309 /opt/omni/databases/vendor/ma/ibm/rs6000/ aix/A.02.10/packet.Z 156930833 1276227 /opt/omni/databases/vendor/ma/sun/sparc/ solaris/A.02.10/packet.Z 3213357040 1341909 /opt/omni/databases/vendor/das/hp/s800/ hp-ux/A.02.10/packet.Z 2590409262 1486524 /opt/omni/databases/vendor/das/hp/s800/ hp-ux-10/A.02.10/packet.Z 46331952 1739780 /opt/omni/databases/vendor/acs/hp/s800/ hp-ux/A.02.10/packet.Z 3221142921 1889520 /opt/omni/databases/vendor/acs/hp/s800/ hp-ux-10/A.02.10/packet.Z 3960810125 1481800 /opt/omni/lbin/rsm 3619460690 1846870 /opt/omni/lbin/bsm Patch Conflicts: None Patch Dependencies: s700: 10.00 10.01 10.10 10.20: PHSS_12865 s800: 10.00 10.01 10.10 10.20: PHSS_12865 Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_15869 Equivalent Patches: PHSS_15868: s700: 9.01 9.03 9.05 9.07 s800: 9.00 9.04 Patch Package Size: 14630 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_16124 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_16124.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_16124.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_16124. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_16124.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_16124.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: "/opt/omni/sbin/omnisv.sh stop" must be executed on the cell server before swinstall is run. After the update, restart OmniBackII using "/opt/omni/sbin/omnisv.sh start". * The Media Agent modules need to be redistributed to the appropriate systems from within the "Cell Administration - Install" window of the OmnibackII graphical user interface before the patch modifications take effect. * The DAS agent module contains an old version of the libaci.sl shared library which is distributed to the clients during the Install step. If the client system has a newer version of this library, then it must be saved before distributing the DAS agent module and put in place again after the module has been distributed to the DAS agent. The full filename of the library is /usr/omni/lib/libaci.sl on HP-UX 9.X and /opt/omni/lib/libaci.sl on HP-UX 10.X. Patch includes the following Site Specific Patches: - SSP_54 - SSP_56 - SSP_57 - SSP_60