Patch Name: PHSS_15793 Patch Description: s700_800 10.X OV OB2.55 patch - MA packet Creation Date: 98/07/20 Post Date: 98/07/24 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.02.55 Filesets: OMNIBACK-II.OMNI-MA-P OMNIBACK-II.OMNI-ACS-P OMNIBACK-II.OMNI-DAS-P Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_15793 Symptoms: PHSS_15793: Id = NSMex01357 If Media Agent failed then OmniBack II sent 2 down commands to GRAU device. Id = NSMbb18594 Problems with enter/eject operations. Id = NSMex01438 Backup to ACS-LS Media Agent failed with: STATUS_LOCKID_NOT_FOUND. Id = NSMex01463 Backup could overwrite part of the data during append. PHSS_15466: Id = NSMex01379 Backup Media Agent for direct access devices corrupted the data on the MO medium. Id = NSMex01411 Backup to the Media Agent running on AIX or Sinix Operating system failed with "Unknown internal error. PHSS_14970: Id = NSMex01041 Backup to MO device on HP-UX 9.x failed with "Can not switch to exclusive access." Id = NSMbb17300 Backup and rescan of an autoloader connected to HP-UX 9.x failed with: "[MINOR] REQUEST SENSE call failed. Invalid Argument." Id = NSMex01052 OmniBack II did not handle eject of media from STK - SILO properly. Id = NSMex01172 OmniBack II did not report correct barcodes during rescan of scsi II libraries. Id = NSMex01215 At the end of a copy session, the error "Can not open device (No such device or address)" was displayed if an exchanger device was used. Id = NSMex01246 Handling of busy drives failed if the exchanger robotic was connected to a different host Id = NSMex01284 Backup could overwrite part of the data during append. PHSS_14337: Id = NSMex01087 The Media Agent failed during backup of the database integration. Defect Description: PHSS_15793: Id = NSMex01357 In the case that media agent failed for some reason, two "DOWN" commands were sent to GRAU. Part of SSP255_57. Id = NSMbb18594 When entering multiple media into a library with only one mailslot, then if a medium was put into the mailslot immediately after the previous one had been taken out, the operation could fail and the medium was not entered into the slot. Part of SSP255_62 and SSP255_73. Id = NSMex01438 If the ACS-LS Media Agent was aborted two unlock commands were sent. Because of that error was shown: "StorageTek ACS error in "acs_unlock": STATUS_LOCKID_NOT_FOUND." Part of SSP255_66. Id = NSMex01463 To append to a medium, omniback uses the seek function which is supposed to fail at the End Of Data. This function could fail for other reasons, causing the write operation to start from a wrong position on the tape and overwriting valid data. An additional check was added to prevent this. If the seek failed then the tape, that was used during seek is marked as poor. Such tape has to be verified. Part of SSP255_68. PHSS_15466: Id = NSMex01379 If the direct access medium (optical disks, disks, files) contained a great number of small backups (maximum 475), there was a possibility of corruption of the data. Number of the segments on the medium is now restricted to 950. Part of SSP255_54. Id = NSMex01411 If the offical patch (PHSS_14970) was installed and during backup the backed up data were appended to the tape then the backup failed with "Unknown internal error". The problem happened only if Media Agent was running on Sinix or on AIX. Part of SSP255_56 PHSS_14970: Id = NSMex01041 Backup to MO device on HP-UX 9.x failed with "Can not switch to exclusive access." Part of SSP255_10. Id = NSMbb17300 Backup and rescan of autoloader connected to HP-UX 9.x failed with: "[MINOR] REQUEST SENSE call failed. Invalid Argument." Part of SSP255_10. Id = NSMex01052 OmniBack II did not handle eject of media from STK-SILO properly if there was one of the selected tapes located in a drive. In such a situation the information about tapes was not properly updated in the OmniBack II DB. Part of SSP255_26. Id = NSMex01172 OmniBack II did not report correct barcodes during rescan of scsi II libraries. Rescan failed. Part of SSP255_30. Id = NSMex01215 Handling for media close was not OK if copy failed for some reason (in particular case because the destination tape was shorter than original). Part of SSP255_39. Id = NSMex01246 Busy drive handling (eject feature) did not work if robotic was on the remote host. Part of SSP255_40. Id = NSMex01284 To append to a medium, omniback uses the seek function which is supposed to fail at the End Of Data. This function could fail for other reasons, causing the write operation to start from a wrong position on the tape and overwriting valid data. An additional check was added to prevent this. Part of SSP255_46. PHSS_14337: Id = NSMex01087 OmniBack II did not handle the end of the database integration backups properly, if at the same time the tape was at the end. As result of it the bma failed with different errors. Part of SSP255_19. SR: 5003422436 5003419937 5003421040 Patch Files: /opt/omni/databases/vendor/ma/hp/s800/hp-ux-10/A.02.55/ packet.Z /opt/omni/databases/vendor/ma/hp/s800/hp-ux/A.02.55/packet.Z /opt/omni/databases/vendor/ma/ibm/rs6000/aix/A.02.55/ packet.Z /opt/omni/databases/vendor/ma/ibm/rs6000/aix-42/A.02.55/ packet.Z /opt/omni/databases/vendor/ma/siemens/r400/sinix/A.02.55/ packet.Z /opt/omni/databases/vendor/ma/sun/sparc/solaris/A.02.55/ packet.Z /opt/omni/databases/vendor/acs/hp/s800/hp-ux/A.02.55/ packet.Z /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/A.02.55/ packet.Z /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/require.dat /opt/omni/databases/vendor/das/hp/s800/hp-ux/A.02.55/ packet.Z /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/A.02.55/ packet.Z /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/require.dat what(1) Output: /opt/omni/databases/vendor/ma/hp/s800/hp-ux-10/A.02.55/ packet.Z: None /opt/omni/databases/vendor/ma/hp/s800/hp-ux/A.02.55/ packet.Z: None /opt/omni/databases/vendor/ma/ibm/rs6000/aix/A.02.55/ packet.Z: None /opt/omni/databases/vendor/ma/ibm/rs6000/aix-42/A.02.55/ packet.Z: None /opt/omni/databases/vendor/ma/siemens/r400/sinix/A.02.55/ packet.Z: None /opt/omni/databases/vendor/ma/sun/sparc/solaris/A.02.55/ packet.Z: None /opt/omni/databases/vendor/acs/hp/s800/hp-ux/A.02.55/ packet.Z: None /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/A.02.55/ packet.Z: None /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/require.dat: None /opt/omni/databases/vendor/das/hp/s800/hp-ux/A.02.55/ packet.Z: None /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/A.02.55/ packet.Z: None /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/require.dat: None cksum(1) Output: 3860242698 1709106 /opt/omni/databases/vendor/ma/hp/s800/ hp-ux-10/A.02.55/packet.Z 1872195221 1553673 /opt/omni/databases/vendor/ma/hp/s800/ hp-ux/A.02.55/packet.Z 201085948 1367411 /opt/omni/databases/vendor/ma/ibm/rs6000/ aix/A.02.55/packet.Z 3418992189 1372718 /opt/omni/databases/vendor/ma/ibm/rs6000/ aix-42/A.02.55/packet.Z 4172066589 1689415 /opt/omni/databases/vendor/ma/siemens/ r400/sinix/A.02.55/packet.Z 1048884736 1636383 /opt/omni/databases/vendor/ma/sun/sparc/ solaris/A.02.55/packet.Z 2831057306 2125465 /opt/omni/databases/vendor/acs/hp/s800/ hp-ux/A.02.55/packet.Z 930075732 2282177 /opt/omni/databases/vendor/acs/hp/s800/ hp-ux-10/A.02.55/packet.Z 3490244583 21 /opt/omni/databases/vendor/acs/hp/s800/ hp-ux-10/require.dat 871670892 1582438 /opt/omni/databases/vendor/das/hp/s800/ hp-ux/A.02.55/packet.Z 3941227621 1734120 /opt/omni/databases/vendor/das/hp/s800/ hp-ux-10/A.02.55/packet.Z 3490244583 21 /opt/omni/databases/vendor/das/hp/s800/ hp-ux-10/require.dat Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_14337 PHSS_14970 PHSS_15466 Equivalent Patches: PHSS_15794: s700: 11.00 s800: 11.00 Patch Package Size: 16730 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_15793 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_15793.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_15793.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_15793. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_15793.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_15793.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: NOTE! Patch has to be installed on the Cell Server host. * The Media Agent package needs to be redistributed to the appropriate systems, where the Media Agent Clients are installed, from within the "Cell Administration - Install" window of the OmnibackII graphical user interface before the patch modifications take effect. NOTE! Make sure that no backup or restore or media management session is running while you distribute the package to the MA clients. In order to resolve Defect with Id NSMex01052, also the OMNIBACK II A.02.55 CS packet patch has to be installed. This is currently PHSS_14853, but may be superseded by a newer version in the future. From PHSS_14970 patch OmniBack II officially supports ACS Library System Integration on HP-UX 11.x. From PHSS_15793 patch OmniBack II officially supports DAS Library System Integration on HP-UX 11.x. Patch includes the following Site Specific Patches: - SSP255_10 - SSP255_19 - SSP255_26 - SSP255_30 - SSP255_39 - SSP255_40 - SSP255_45 - SSP255_46 - SSP255_54 - SSP255_56 - SSP255_57 - SSP255_62 - SSP255_66 - SSP255_68 - SSP255_73