Patch Name: PHSS_14337 Patch Description: s700_800 10.X OV OB2.55 patch - MA packet Creation Date: 98/03/05 Post Date: 98/03/13 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.02.55 Filesets: OMNIBACK-II.OMNI-MA-P OMNIBACK-II.OMNI-ACS-P OMNIBACK-II.OMNI-DAS-P Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_14337 Symptoms: PHSS_14337: 1. Id = NSMex01087 The Media Agent failed during backup of the database integration. Defect Description: PHSS_14337: 1. Id = NSMex01087 OmniBack II did not handle the end of the database integration backups properly, if at the same time the tape was at the end. As result of it the bma failed with different errors. Part of SSP255_19. SR: 0000000000 Patch Files: /opt/omni/databases/vendor/ma/hp/s800/hp-ux-10/A.02.55/ packet.Z /opt/omni/databases/vendor/ma/hp/s800/hp-ux/A.02.55/packet.Z /opt/omni/databases/vendor/acs/hp/s800/hp-ux/A.02.55/ packet.Z /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/A.02.55/ packet.Z /opt/omni/databases/vendor/das/hp/s800/hp-ux/A.02.55/ packet.Z /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/A.02.55/ packet.Z what(1) Output: /opt/omni/databases/vendor/ma/hp/s800/hp-ux-10/A.02.55/ packet.Z: None /opt/omni/databases/vendor/ma/hp/s800/hp-ux/A.02.55/ packet.Z: None /opt/omni/databases/vendor/acs/hp/s800/hp-ux/A.02.55/ packet.Z: None /opt/omni/databases/vendor/acs/hp/s800/hp-ux-10/A.02.55/ packet.Z: None /opt/omni/databases/vendor/das/hp/s800/hp-ux/A.02.55/ packet.Z: None /opt/omni/databases/vendor/das/hp/s800/hp-ux-10/A.02.55/ packet.Z: None cksum(1) Output: 498571893 1690571 /opt/omni/databases/vendor/ma/hp/s800/ hp-ux-10/A.02.55/packet.Z 1974396247 1537439 /opt/omni/databases/vendor/ma/hp/s800/ hp-ux/A.02.55/packet.Z 4255784072 2115827 /opt/omni/databases/vendor/acs/hp/s800/ hp-ux/A.02.55/packet.Z 2276904789 2271737 /opt/omni/databases/vendor/acs/hp/s800/ hp-ux-10/A.02.55/packet.Z 1227230277 1569137 /opt/omni/databases/vendor/das/hp/s800/ hp-ux/A.02.55/packet.Z 1215211004 1727382 /opt/omni/databases/vendor/das/hp/s800/ hp-ux-10/A.02.55/packet.Z Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_14338: s700: 11.00 s800: 11.00 Patch Package Size: 10720 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_14337 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_14337.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_14337.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_14337. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_14337.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_14337.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: SUBSYSTEM_SHUT NOTE! Patch has to be installed on the Cell Server host. * The Media Agent package needs to be redistributed to the appropriate systems, where the Media Agent Clients are installed, from within the "Cell Administration - Install" window of the OmnibackII graphical user interface before the patch modifications take effect. NOTE! Make sure that no backup or restore or media management session is running while you distribute the package to the MA clients.