Patch Name: PHSS_12455 Patch Description: s700_800 10.20 PEX 5.1/Starbase/Hardcopy Runtime patch Creation Date: 97/08/24 Post Date: 97/09/24 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: N/A Filesets: GraphicsCommon.SBDL-SHLIBS GraphicsCommon.STAR-SHLIBS Xserver.AGRM Automatic Reboot?: Yes Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_12455 Symptoms: PHSS_12455: - See defect description. Defect Description: PHSS_12455: - A 720,730, or 750 SPU with CRX24Z or CRX48Z graphics fails with an illegal instruction using Starbase, PEX or PHIGS. This defect was introduced with the 10.20 ACE bundle. - Applications using immediate mode PEXOCCpolylines on VisualizeFX devices may experience problems (with a variety of unpredictable symptoms) because the graphics library does not restore processor registers correctly for this path. - Some problems with PHIGS regenerations, especially after repeated structure edits, have been repaired. - When an application is trying to perform graphics on Visualize devices while using DCE threads the application is likely to get a segmentation fault at the first gopen. SR: 0000000000 Patch Files: /opt/graphics/common/lib/2fc1066block.1 /opt/graphics/common/lib/dilocking.1 /opt/graphics/common/lib/libddcrx48z.1 /opt/graphics/common/lib/libddgcrx.1 /opt/graphics/common/lib/libddvisx.1 /opt/graphics/common/lib/libdl.1 /opt/graphics/common/lib/libhpgfx.1 /opt/graphics/common/lib/libhpgfx.2 what(1) Output: /opt/graphics/common/lib/2fc1066block.1: Graphics Lock Library on HP-UX 10.20 $Date: 13-Sep-9 7.00:01:02 $ $Revision: 19970913.150 $ 2fc10 66block.1 /opt/graphics/common/lib/dilocking.1: Graphics Lock Library on HP-UX 10.20 $Date: 12-Sep-9 7.23:59:30 $ $Revision: 19970912.150 $ diloc king.1 /opt/graphics/common/lib/libddcrx48z.1: PHSS_12455/12456 SB Runtime/DevKit GRAPHICS CORE on HP-UX 10.20 $Date: 13-Sep-97.00:01: 54 $ $Revision: 19970913.1200 $ libddcrx48z. 1 /opt/graphics/common/lib/libddgcrx.1: PHSS_12455/12456 SB Runtime/DevKit GRAPHICS CORE on HP-UX 10.20 $Date: 13-Sep-97.00:01: 54 $ $Revision: 19970913.1200 $ libddgcrx.1 /opt/graphics/common/lib/libddvisx.1: PHSS_12455/12456 SB Runtime/DevKit GRAPHICS CORE on HP-UX 10.20 $Date: 13-Sep-97.00:01: 54 $ $Revision: 19970913.1200 $ libddvisx.1 /opt/graphics/common/lib/libdl.1: PHSS_12455/12456 SB Runtime/DevKit GRAPHICS CORE on HP-UX 10.20 $Date: 13-Sep-97.00:01: 54 $ $Revision: 19970913.1200 $ libdl.1 /opt/graphics/common/lib/libhpgfx.1: PHSS_12455/12456 SB Runtime/DevKit PHSS_12455/12456 SB Runtime/DevKit PHSS_12455/12456 SB Runtime/DevKit GRAPHICS CORE on HP-UX 10.20 $Date: 13-Sep-97.00:01: 54 $ $Revision: 19970913.1200 $ libhpgfx.1 /opt/graphics/common/lib/libhpgfx.2: PHSS_12455/12456 SB Runtime/DevKit PHSS_12455/12456 SB Runtime/DevKit PHSS_12455/12456 SB Runtime/DevKit GRAPHICS CORE on HP-UX 10.20 $Date: 13-Sep-97.00:01: 54 $ $Revision: 19970913.1200 $ libhpgfx.2 cksum(1) Output: 244812022 24674 /opt/graphics/common/lib/2fc1066block.1 1881398630 24637 /opt/graphics/common/lib/dilocking.1 753672113 246345 /opt/graphics/common/lib/libddcrx48z.1 1293458407 344799 /opt/graphics/common/lib/libddgcrx.1 2960177569 505039 /opt/graphics/common/lib/libddvisx.1 3891094595 530027 /opt/graphics/common/lib/libdl.1 3732118547 2812269 /opt/graphics/common/lib/libhpgfx.1 832661536 2812269 /opt/graphics/common/lib/libhpgfx.2 Patch Conflicts: None Patch Dependencies: s700: 10.20: PHSS_11399 s800: 10.20: PHSS_11399 Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: None Patch Package Size: 7200 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_12455 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_12455.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_12455.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_12455. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_12455.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_12455.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: None