Patch Name: PHSS_11835 Patch Description: s700_800 10.X OV ITO3.0x Agent for HP-UX 10.X Creation Date: 97/07/28 Post Date: 97/07/31 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OpenView IT/Operations 3.0x Filesets: OVOPC-CLT.OVOPC-UX10-CLT OVOPC-CLT-ENG.OVOPC-UX10-CLT Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_11835 Symptoms: PHSS_11835: - configuration distribution sometimes report problems connecting to the TCP socket server. - supression of identical messages does not work. - memory leak in opcle Defect Description: PHSS_11835: check the list of the symptoms SR: 0000000000 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/vp_chk.sh.Z what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/dist_del.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/mailq_pr.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/pv.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/st_inetd.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/actions/st_mail.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/cmds/opcdf.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/cmds/opclpst.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/cmds/opcps.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrclchk: HP OpenView IT/Operations A.03.01 (09/12/96) OpC A.03.01 (09/12/96) OpC A.03.01 (09/12/96) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrdschk: HP OpenView IT/Operations A.03.01 (09/12/96) OpC A.03.01 (09/12/96) OpC A.03.01 (09/12/96) OpC A.03.01 (09/12/96) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrinst: HP OpenView IT/Operations A.03.01 (10/01/96) OpC A.03.01 (10/01/96) OpC A.03.01 (10/01/96) OpC A.03.01 (10/01/96) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrndchk: HP OpenView IT/Operations A.03.01 (09/12/96) OpC A.03.01 (09/12/96) OpC A.03.01 (09/12/96) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcroschk: HP OpenView IT/Operations A.03.01 (09/12/96) OpC A.03.01 (09/12/96) OpC A.03.01 (09/12/96) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/install/opcrverchk: HP OpenView IT/Operations A.03.01 (09/12/96) OpC A.03.01 (09/12/96) OpC A.03.01 (09/12/96) OpC A.03.01 (09/12/96) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/ana_disk.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/cpu_mon.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/disk_mon.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/dist_mon.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/last_logs.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/mailq_l.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/mwa_read.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/opcfwtmp.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/opcnprcs.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/perf_alxp.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/proc_mon.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/sh_procs.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/swap_mon.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/monitor/vp_chk.sh.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.03.07/opc_pkg.Z: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform: None. /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform: None. cksum(1) Output: 3387946056 4774 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/actions/dist_del.sh.Z 3299706386 2564 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/actions/mailq_pr.sh.Z 2927896529 4457 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/actions/pv.sh.Z 2428284304 2551 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/actions/st_inetd.sh.Z 3499457631 2587 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/actions/st_mail.sh.Z 3369944691 346 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/cmds/opcdf.Z 2210929757 359 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/cmds/opclpst.Z 1625841832 386 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/cmds/opcps.Z 258239324 6898 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/install/opcrclchk 2237599254 28728 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/install/opcrdschk 293908257 87198 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/install/opcrinst 1874613636 6684 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/install/opcrndchk 633996771 6298 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/install/opcroschk 4027670944 25845 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/install/opcrverchk 2601673299 2591 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/ana_disk.sh.Z 939934884 4631 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/cpu_mon.sh.Z 1867328505 4723 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/disk_mon.sh.Z 3522821324 4679 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/dist_mon.sh.Z 2991218715 4534 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/ last_logs.sh.Z 1698910274 4514 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/mailq_l.sh.Z 1321875527 4546 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/mwa_read.sh.Z 1003650029 5509 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/opcfwtmp.Z 2123508770 4999 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/opcnprcs.Z 1168053834 3140 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/ perf_alxp.sh.Z 49023608 4670 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/proc_mon.sh.Z 190837421 4117 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/sh_procs.sh.Z 3003567067 4619 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/swap_mon.sh.Z 3747422138 4366 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/monitor/vp_chk.sh.Z 1653015210 2465679 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.03.07/opc_pkg.Z 2302136756 4775 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/AgentPlatform 228722904 4758 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux10/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_11834: s700: 9.01 9.03 9.05 9.07 s800: 9.00 9.04 Patch Package Size: 2760 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_11835 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_11835.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_11835.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_11835. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_11835.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_11835.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: - This patch may only be installed on top of one of the following ITO releases: A.03.0X - DO NOT use this patch with previous releases of OpC, for example versions A.01.X A.02.X - All functionality contained in this patch will be included in the next official release of HP OpenView IT/Operations (ITO) release. - This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on Managed Nodes by means of ITO Software Distribution. - Depending on your SD version: If you can't swinstall from the patch depot, you may need the swinstall option "-x source_type=tape"