Patch Name: PHCO_23148 Patch Description: s700_800 10.20 HP Array Manager/60 cumulative patch Creation Date: 01/02/22 Post Date: 01/02/23 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: N/A Filesets: OS-Core.ADMN-ENG-A-MAN OS-Core.C2400-UTIL Automatic Reboot?: No Status: General Superseded Critical: Yes PHCO_23148: OTHER Patch provides critical functionality for use of HP Fibre Array/60 devices. Path Name: /hp-ux_patches/s700_800/10.X/PHCO_23148 Symptoms: PHCO_23148: 1. JAGad45524 - FC60 controller may attempt back-end I/O during disk mech firmware download, resulting in Selection Timeout error. 2. JAGad45915 - Parity scan does not report error blocks. 3. JAGad49307 - amdload core dump after controller firmware download, while waiting for completion of reset, if timeout occurs while polling AM60Srvr for status. 4. JAGad49298 - amdsp core dump on fully loaded FC60 with misconfigured ID thumbwheels. 5. JAGad49309 - Downloading 4.X firmware or NVSRAM to passive controller may be problematic. Separate command sometimes required to restore controller to active mode. 6. JAGad49088 - swremove of HP Array Manager/60 patch causes /etc/rc.config.d/hparamgr file to be removed, preventing automatic restart of daemon on reboot. 7. JAGad51090 - On HP-UX 10.20 patch install/remove, swmodify attempts to access non-existent filesets of name type PATCH_ID.PATCH_ID. PHCO_22627: 1. JAGad35936 - Fix log clearing problem with HP03 and earlier firmware, introduced in PHCO_22195. 2. JAGad34226 - Change MEL drive slot from 1-based to 0-based, to match amdsp output. Problem was introduced in PHCO_22195. 3. JAGad36256 - Implement environment variable to allow option for more than 100 MB of log files. 4. JAGad36259 - Add non-redundancy warnings for RAID 0. 5. The amlog utility provided in this patch does not read the array log files generated by AM60Srvr from PHCO_21314 or earlier patches. To read old log files, use the archived version of amlog found in /var/adm/sw/patch//opt/hparray/bin/, where OLD_PATCH_NAME is PHCO_21314 or earlier. PHCO_22195: 1. JAGad04079 - AM60Srvr core dumps on parity scan of LUN with owning controller missing. 2. JAGab16618 - Improve logging in multi-initiator environments. 3. JAGab84551 - SCSI Device Lock Not Granted when attempting syswipe of array. 4. JAGac00096 - LUN recovery difficult. 5. JAGad08697 - AM60Srvr dies intermittently. 6. JAGad23891 - amdload command lock violation. 7. JAGab78599 - Implement Major Event Logging in AM60. 8. JAGac79027 - AM60Srvr exits with PendingQueue::Add buffer overflow. 9. JAGad26497 - LUN display shows drives as ?-? when numDisks is 0. 10. JAGad03253 - Download application firmware and bootware as one file. 11. JAGab82780 - amdsp command fails after LUN's owning controller is removed. 12. JAGad03254 - Add support for RAID 0 LUNs. 13. JAGad03945 - Add support for UTM LUN. 14. JAGad07307 - Handle new sense codes from HP07 firmware. 15. JAGad27589 - Handle SCSI disk firmware convergence in amdload. 16. JAGab15596 - Log files should not be able to grow so as to overflow a file system. 17. JAGac86825 - Disk firmware download problems on Seagate Cheetah III & IV mechs. 18. JAGad02941 - FRU device type 0x07 not always decoded correctly in amlog. 19. JAGad03204 - Enable software controller reset when allowed by firmware. 20. JAGad03821 - LUN number sometimes not initialized in drive group display. 21. JAGad10447 - New FRU group decoding required with HP07 controller firmware. 22. JAGad10909 - Man page updates required for IPR-0012 software. 23. JAGad23902 - Decode FRU info provided in raw MEL data. 24. JAGab78603 - Validate AM60 ANSI C++ compliance. 25. JAGad02940 - Add support for LUN state 83. 26. JAGad05381 - Report disk sense data on SMART events. 27. JAGad07400 - Slot ID in disk display has wrong data type. 28. JAGab75343 - Fix amlog memory leak. 29. JAGab75346 - Fix amdload memory leak. 30. JAGad16493 - amdsp -p -S on more than two links results in a device ID error. 31. JAGad29621 - amdsp -i reports AM60Srvr unavailable, but it is running. PHCO_21314: 1. JAGad00714 - Change connection messages going to syslog from info type to debug type. Also change rescan message to be debug as well. PHCO_20217: 1. JAGac33875 - AM60Srvr only logs events when LUN 1 is configured. 2. JAGab78816 - amlog does not show LUN info when a LUN is failed with unflushed cache. 3. JAGac39733 - AM60Srvr fails with core on startup on systems with more than ten FC-60 arrays attached. 4. JAGac40880 - amfmt command requires change to man page to indicate that it is a data destructive command. 5. JAGac39742 - amlog does not decode all sense codes. 6. JAGab76959 - amcfg fails with segmentation violation if an invalid channel is specified when configuring a LUN. 7. JAGac29676 - make amcfg bind LUN default segment size 16K, instead of current cache block size. 8. JAGab32006 - Minor typographical error in amcfg man page 9. JAGac79070 - Need to re-designate SC-10 power supplies and fans as A, B instead of 1, 2. 10. JAGac86303 - Change "ARM" reference to "AM60" in amlog output and syslog file, when a required message catalog entry can't be found. PHCO_19485: 1. JAGab20973 - Incorrect diagnostic message when specifying alias longer than 16 characters. 2. JAGab24502 - Unclear diagnostic message when binding a LUN on a passive controller. 3. JAGab25356 - Ambiguous cache battery age shown in controller display. 4. JAGab14439 - Rounding problem when setting and displaying cache flush options. 5. JAGab18057 - Need to add interpretation of FRU code and qualifier for amlog. 6. JAGab57569 - SCSI channel, SCSI ID, enclosure ID and slot ID are ambiguous in disk display. 7. JAGab21223 - amdsp fails with core file during LUN display when all original drives are spared. 8. JAGab39222 - Need improved handling of commands which require controller synchronization (reset battery age, set time, set alias), when one controller is missing or failed. 9. JAGab67460 - Need capability to mark disks operational from any failed state. 10. JAGab68932 - Need an option for amdload to allow BCC firmware download regardless of disk states. 11. JAGab43951 - Need to show NVSRAM version in controller display. 12. JAGab43865 - Need capability to reset LUN cache parameters to default values, and show a cache state table in the LUN display. 13. JAGab17231 - Command line extended help and usage messages need to be more consistent with man pages. 14. JAGab65570 - amdload man page must describe requirement to download bootware, firmware, NVSRAM file in proper sequence. 15. JAGab70912 - Need capability to flash LEDs for a drive list. 16. Need SIC HWPath call to allow EMS client to report array hardware path. 17. JAGab72268 - Need capability to download firmware to IBM disks. 18. Client/server interface (SIC) needs forward and backward compatibility to support EMS monitor. 19. JAGab31757 - amdsp may fail with core file, Segmentation violation. PHCO_18684: Initial Release Install Patch. Defect Description: PHCO_23148: 1. Description: JAGad45524 - FC60 controller may attempt back-end I/O during disk mech firmware download, resulting in Selection Timeout error. 2. Description: JAGad45915 - Parity scan does not report error blocks. 3. Description: JAGad49307 - amdload core dump after controller firmware download, while waiting for completion of reset, if timeout occurs while polling AM60Srvr for status. 4. Description: JAGad49298 - amdsp core dump on fully loaded FC60 with misconfigured ID thumbwheels. 5. Description: JAGad49309 - Downloading 4.X firmware or NVSRAM to passive controller may be problematic. Separate command sometimes required to restore controller to active mode. 6. Description: JAGad49088 - swremove of HP Array Manager/ 60 patch causes /etc/rc.config.d/hparamgr file to be removed, preventing automatic restart of daemon on reboot. 7. Description: JAGad51090 - On HP-UX 10.20 patch install/ remove, swmodify attempts to access non-existent filesets of name type PATCH_ID.PATCH_ID. NOTE: If any of the superceded patches have been installed, and this patch is later removed, the revision numbers of the superceded patches, as shown by swlist, will be incorrectly displayed as B.10.00.00.AA. The actual revision numbers are as follows: PHCO_22627 - B.10.20.13, PHCO_22195 - B.10.20.11, PHCO_21314 - B.10.20.10, PHCO_20217 - B.10.20.9, PHCO_19485 - B.10.20.7, PHCO_18684 - B.10.20.4. PHCO_22627: 1. Description: JAGad35936 - Fix log clearing problem with HP03 and earlier firmware, introduced in PHCO_22195. 2. Description: JAGad34226 - Change MEL drive slot from 1-based to 0-based, to match amdsp output. Problem was introduced in PHCO_22195. 3. Description: JAGad36256 - Implement environment variable to allow option for more than 100 MB of log files. 4. Description: JAGad36259 - Add non-redundancy warnings for RAID 0. 5. Description: The amlog utility provided in this patch does not read the array log files generated by AM60Srvr from PHCO_21314 or earlier patches. To read old log files, use the archived version of amlog found in /var/adm/sw/patch//opt/ hparray/bin/, where OLD_PATCH_NAME is PHCO_21314 or earlier. PHCO_22195: 1. Description: JAGad04079 - AM60Srvr core dumps on parity scan of LUN with owning controller missing. 2. Description: JAGab16618 - Improve logging in multi-initiator environments. 3. Description: JAGab84551 - SCSI Device Lock Not Granted when attempting syswipe of array. 4. Description: JAGac00096 - LUN recovery difficult. 5. Description: JAGad08697 - AM60Srvr dies intermittently. 6. Description: JAGad23891 - amdload command lock violation. 7. Description: JAGab78599 - Implement Major Event Logging in AM60. 8. Description: JAGac79027 - AM60Srvr exits with PendingQueue::Add buffer overflow. 9. Description: JAGad26497 - LUN display shows drives as ?-? when numDisks is 0. 10. Description: JAGad03253 - Download application firmware and bootware as one file. 11. Description: JAGab82780 - amdsp command fails after LUN's owning controller is removed. 12. Description: JAGad03254 - Add support for RAID 0 LUNs. 13. Description: JAGad03945 - Add support for UTM LUN. 14. Description: JAGad07307 - Handle new sense codes from HP07 firmware. 15. Description: JAGad27589 - Handle SCSI disk firmware convergence in amdload. 16. Description: JAGab15596 - Log files should not be able to grow so as to overflow a file system. 17. Description: JAGac86825 - Disk firmware download problems on Seagate Cheetah III & IV mechs. 18. Description: JAGad02941 - FRU device type 0x07 not always decoded correctly in amlog. 19. Description: JAGad03204 - Enable software controller reset when allowed by firmware. 20. Description: JAGad03821 - LUN number sometimes not initialized in drive group display. 21. Description: JAGad10447 - New FRU group decoding required with HP07 controller firmware. 22. Description: JAGad10909 - Man page updates required for IPR-0012 software. 23. Description: JAGad23902 - Decode FRU info provided in raw MEL data. 24. Description: JAGab78603 - Validate AM60 ANSI C++ compliance. 25. Description: JAGad02940 - Add support for LUN state 83. 26. Description: JAGad05381 - Report disk sense data on SMART events. 27. Description: JAGad07400 - Slot ID in disk display has wrong data type. 28. Description: JAGab75343 - Fix amlog memory leak. 29. Description: JAGab75346 - Fix amdload memory leak. 30. Description: JAGad16493 - amdsp -p -S on more than two links results in a device ID error. 31. Description: JAGad29621 - amdsp -i reports AM60Srvr unavailable, but it is running. PHCO_21314: 1. Description: JAGad00714 - Change connection messages going to syslog from info type to debug type. Also change rescan message to be debug as well. PHCO_20217: 1. Description: JAGac33875 - AM60Srvr only logs events when LUN 1 is configured. 2. Description: JAGab78816 - amlog does not show LUN info when a LUN is failed with unflushed cache. 3. Description: JAGac39733 - AM60Srvr fails with core on startup on systems with more than ten FC-60 arrays attached. 4. Description: JAGac40880 - amfmt command requires change to man page to indicate that it is a data destructive command. 5. Description: JAGac39742 - amlog does not decode all sense codes. 6. Description: JAGab76959 - amcfg fails with segmentation violation if an invalid channel is specified when configuring a LUN. 7. Description: JAGac29676 - make amcfg bind LUN default segment size 16K, instead of current cache block size. 8. Description: JAGab32006 - Minor typographical error in amcfg man page. 9. Description: JAGac79070 - Need to re-designate SC-10 power supplies and fans as A, B instead of 1, 2. 10. Description: JAGac86303 - Change "ARM" reference to "AM60" in amlog output and syslog file, when a required message catalog entry can't be found. PHCO_19485: 1. Description: JAGab20973 - Incorrect diagnostic message when specifying alias longer than 16 characters. 2. Description: JAGab24502 - Unclear diagnostic message when binding a LUN on a passive controller. 3. Description: JAGab25356 - Ambiguous cache battery age shown in controller display. 4. Description: JAGab14439 - Rounding problem when setting and displaying cache flush options. 5. Description: JAGab18057 - Need to add interpretation of FRU code and qualifier for amlog. 6. Description: JAGab57569 - SCSI channel, SCSI ID, enclosure ID and slot ID are ambiguous in disk display. 7. Description: JAGab21223 - amdsp fails with core file during LUN display when all original drives are spared. 8. Description: JAGab39222 - Need improved handling of commands which require controller synchronization (reset battery age, set time, set alias), when one controller is missing or failed. 9. Description: JAGab67460 - Need capability to mark disks operational from any failed state. 10. Description: JAGab68932 - Need an option for amdload to allow BCC firmware download regardless of disk states. 11. Description: JAGab43951 - Need to show NVSRAM version in controller display. 12. Description: JAGab43865 - Need capability to reset LUN cache parameters to default values, and show a cache state table in the LUN display. 13. Description: JAGab17231 - Command line extended help and usage messages need to be more consistent with man pages. 14. Description: JAGab65570 - amdload man page must describe requirement to download bootware, firmware, NVSRAM file in proper sequence. 15. Description: JAGab70912 - Need capability to flash LEDs for a drive list. 16. Description: Need SIC HWPath call to allow EMS client to report array hardware path. 17. Description: JAGab72268 - Need capability to download firmware to IBM disks. 18. Description: Client/server interface (SIC) needs forward and backward compatibility to support EMS monitor. 19. Description: JAGab31757 - amdsp may fail with core file, Segmentation violation. PHCO_18684: 1. Description: Initial Release Install Patch. SR: 4700000000 Patch Files: /opt/hparray/bin/AM60Srvr /opt/hparray/bin/amcfg /opt/hparray/bin/amdsp /opt/hparray/bin/amfmt /opt/hparray/bin/amutil /opt/hparray/bin/ammgr /opt/hparray/bin/amlog /opt/hparray/bin/amdload /opt/hparray/lib/nls/msg/C/AM60Srvr.cat /opt/hparray/lib/nls/msg/C/am60cl.cat /opt/hparray/lib/nls/msg/C/am60oemmsg01.cat /opt/hparray/lib/nls/msg/C/am60fwerrcod.cat /usr/lbin/hparray/hparamail /usr/lbin/hparray/hparamgr.hdr /usr/lbin/hparray/hparamgrd /usr/lbin/hparray/hparamgrrc /sbin/init.d/hparamgr /usr/newconfig/etc/rc.config.d/hparamgr /opt/hparray/share/man/man1m/AM60Srvr.1m /opt/hparray/share/man/man1m/amcfg.1m /opt/hparray/share/man/man1m/amdsp.1m /opt/hparray/share/man/man1m/amfmt.1m /opt/hparray/share/man/man1m/amlog.1m /opt/hparray/share/man/man1m/ammgr.1m /opt/hparray/share/man/man1m/amutil.1m /opt/hparray/share/man/man1m/amdload.1m what(1) Output: /opt/hparray/bin/AM60Srvr: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-Copyright (c) 1995 Hewlett-Packard Company | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 - Server +-HP Array Manager/60 - HP Shim | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company sascsidev_init.c, $Revision: 1.1 $ sascsidev_init_lun.c, $Revision: 1.1 $ sascsidev_init_dev_file.c, $Revision: 1.1 $ sascsidev_lock.c, $Revision: 1.1 $ sascsidev_io.c, $Revision: 1.1 $ sascsidev_unlock.c, $Revision: 1.1 $ sascsidev_end.c, $Revision: 1.3 $ sascsidev_io_diag0.c, $Revision: 1.1 $ sascsidev_io_sctl.c, $Revision: 1.1 $ sascsidev_gen.c, $Revision: 1.1 $ tl_io_init.c, $Revision: 1.1 $ tl_path_to_token.c, $Revision: 1.1 $ tl_get_driver_name.c, $Revision: 1.1 $ tl_io_end.c, $Revision: 1.1 $ tl_get_minor_number.c, $Revision: 1.1 $ tl_get_c_major.c, $Revision: 1.1 $ tl_diag0_init.c, $Revision: 1.1 $ tl_diag0_lock.c, $Revision: 1.1 $ tl_diag0_unlock.c, $Revision: 1.1 $ tl_diag0_end.c, $Revision: 1.1 $ pl_init_st_log_global.c, $Revision: 1.1 $ sys_test.c, $Revision: 1.1 $ tl_get_ioerrno_parm.c, $Revision: 1.1 $ tl_diag0_acc_errno.c, $Revision: 1.1 $ tl_diag0_send_buff.c, $Revision: 1.1 $ tl_diag0_return_buff.c, $Revision: 1.1 $ tl_diag0_get_buff.c, $Revision: 1.1 $ tl_diag0_scsi_io_setup.c, $Revision: 1.1 $ tl_diag0_log_rel.c, $Revision: 1.1 $ add_lit_parm.c, $Revision: 1.1 $ add_msg_parm.c, $Revision: 1.1 $ build_ll_msg.c, $Revision: 1.1 $ log_ll_msg.c, $Revision: 1.1 $ release_ll_msg.c, $Revision: 1.1 $ +-HP Array Manager/60 - Server Interface Component | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/amcfg: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-Copyright (c) 1995 Hewlett-Packard Company | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 - Client +-HP Array Manager/60 - Server Interface Component | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/amdsp: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-Copyright (c) 1995 Hewlett-Packard Company | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 - Client +-HP Array Manager/60 - Server Interface Component | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/amfmt: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-Copyright (c) 1995 Hewlett-Packard Company | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 - Client +-HP Array Manager/60 - Server Interface Component | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/amutil: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-Copyright (c) 1995 Hewlett-Packard Company | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 - Client +-HP Array Manager/60 - Server Interface Component | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/ammgr: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-Copyright (c) 1995 Hewlett-Packard Company | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 - Client +-HP Array Manager/60 - Server Interface Component | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/amlog: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-HP Array Manager/60 - Standalone Utility | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/amdload: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 +-Copyright (c) 1995 Hewlett-Packard Company | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) | Version: B.10.20.14 +-HP Array Manager/60 - Client +-HP Array Manager/60 - Server Interface Component | Version: B.10.20.14 | (built for: HP-UX on B.10.20 2001/02/22 20:10:46) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/AM60Srvr.cat: HP AutoRAID [B.10.20.14] AM60Srvr.cat $Revision: 1.1 6 $ Built for HP-UX B.10.20 on 2001/02/22 20:10:46 PM MDT (c) Copyright 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/am60fwerrcod.cat: HP AutoRAID [B.10.20.14] fwerrcod.cat $Revision: 1.9 $ Built for HP-UX B.10.20 on 2001/02/22 20:10:46 PM MDT (c) Copyright 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/am60cl.cat: HP AutoRAID [B.10.20.14] am60cl.cat $Revision: 1.60 $ Built for HP-UX B.10.20 on 2001/02/22 20:10:46 PM MDT (c) Copyright 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/am60oemmsg01.cat: HP AutoRAID [B.10.20.14] oemmsg01.cat $Revision: 1.6 $ Built for HP-UX B.10.20 on 2001/02/22 20:10:46 PM MDT (c) Copyright 1995 Hewlett-Packard Company /usr/lbin/hparray/hparamail: +-HP Array Manager - Mail Script | Version: B.11.00.00 +-Copyright (c) 1999 Hewlett-Packard Company /usr/lbin/hparray/hparamgr.hdr: +-HP Array Manager - Script Header | Version: B.11.00.00 +-Copyright (c) 1999 Hewlett-Packard Company /usr/lbin/hparray/hparamgrd: +-HP Array Manager - Monitor Daemon | Version: B.11.00.00 +-Copyright (c) 1999 Hewlett-Packard Company /usr/lbin/hparray/hparamgrrc: +-HP Array Manager - Startup Script | Version: B.11.00.00 +-Copyright (c) 1999 Hewlett-Packard Company /sbin/init.d/hparamgr: +-HP Array Manager - Startup/Shutdown Script | Version: B.11.00.00 +-Copyright (c) 1999 Hewlett-Packard Company /usr/newconfig/etc/rc.config.d/hparamgr: None /opt/hparray/share/man/man1m/AM60Srvr.1m: None /opt/hparray/share/man/man1m/amcfg.1m: None /opt/hparray/share/man/man1m/amdsp.1m: None /opt/hparray/share/man/man1m/amfmt.1m: None /opt/hparray/share/man/man1m/amutil.1m: None /opt/hparray/share/man/man1m/ammgr.1m: None /opt/hparray/share/man/man1m/amlog.1m: None /opt/hparray/share/man/man1m/amdload.1m: None cksum(1) Output: 1001125669 2608400 /opt/hparray/bin/AM60Srvr 2802087634 1107664 /opt/hparray/bin/amcfg 2999291791 1268568 /opt/hparray/bin/amdsp 2411827029 1080352 /opt/hparray/bin/amfmt 2289815925 1101928 /opt/hparray/bin/amutil 1191376108 1111192 /opt/hparray/bin/ammgr 1877957277 1046920 /opt/hparray/bin/amlog 2264293212 1136416 /opt/hparray/bin/amdload 2258219791 7623 /opt/hparray/lib/nls/msg/C/AM60Srvr.cat 3319158706 8868 /opt/hparray/lib/nls/msg/C/am60fwerrcod.cat 299955134 113621 /opt/hparray/lib/nls/msg/C/am60cl.cat 3217585616 1383 /opt/hparray/lib/nls/msg/C/am60oemmsg01.cat 212830779 4931 /usr/lbin/hparray/hparamail 1655478901 3564 /usr/lbin/hparray/hparamgr.hdr 830060169 5893 /usr/lbin/hparray/hparamgrd 4267444545 2873 /usr/lbin/hparray/hparamgrrc 1647493802 5822 /sbin/init.d/hparamgr 999677066 199 /usr/newconfig/etc/rc.config.d/hparamgr 3615556153 3418 /opt/hparray/share/man/man1m/AM60Srvr.1m 3577060457 14504 /opt/hparray/share/man/man1m/amcfg.1m 2389533511 17293 /opt/hparray/share/man/man1m/amdsp.1m 1226416682 799 /opt/hparray/share/man/man1m/amfmt.1m 1747734987 7890 /opt/hparray/share/man/man1m/amutil.1m 2291579198 10467 /opt/hparray/share/man/man1m/ammgr.1m 1899341439 10153 /opt/hparray/share/man/man1m/amlog.1m 2068729702 10005 /opt/hparray/share/man/man1m/amdload.1m Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: This patch provides the utilities for the HP Fibre Array/60. To use the utilities an HP Fibre Array/60 array must be connected and configured to the system. Supersedes: PHCO_18684 PHCO_19485 PHCO_20217 PHCO_21314 PHCO_22195 PHCO_22627 Equivalent Patches: PHCO_23149: s700: 11.00 s800: 11.00 PHCO_23150: s700: 11.11 s800: 11.11 Patch Package Size: 10550 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHCO_23148 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHCO_23148.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHCO_23148. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHCO_23148.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHCO_23148.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: None