Release Notes for ProLiant Support Pack for United Linux/SLES8, v7.30 ******************************** aic7xxx-6.3.10-1.ul10_sp3.i586.rpm - HP ProLiant 64-Bit/66-Mhz Dual Channel Wide Ultra3 SCSI Controller Driver for UnitedLinux 1.0, v6.3.10-1 Enhancements Added support for the following kernels: Version 2.4.21-138 Version 2.4.21-251 ******************************** mptlinux-2.05.16.01-12.ul10.i586.rpm - HP ProLiant 64-Bit/133-MHz Ultra320 Adapter (x86 & AMD32) Driver for SUSE LINUX Enterprise Server 8 (x86), v2.05.16.01-12 Enhancements The kernels of SuSE Linux supported by this binary rpm are: 2.4.21-138 – United Linux 1.0 SP3 (x86) 2.4.21-169 2.4.21-190 2.4.21-196 2.4.21-198 2.4.21-215 2.4.21-226 2.4.21-238 2.4.21-241 ******************************** mptlinux-2.05.16.01-12.ul10.amd64.rpm - HP ProLiant 64-Bit/133-MHz Ultra320 Adapter (AMD64) Driver for SUSE LINUX Enterprise Server 8 (AMD64), v2.05.16.01-12 Enhancements Added support for new kernels. The kernels of SuSE Linux supported by this binary rpm are: 2.4.21-143 – United Linux 1.0 SP3 (AMD64) 2.4.21-207 2.4.21-215 2.4.21-226 2.4.21-238 2.4.21-241 ******************************** hpacucli-7.30-9.linux.rpm - HP Array Configuration Utility CLI for Linux, v7.30-9 Enhancements Added support for the following: Smart Array P600 controller. Active-Active on redundant controllers that support it. ******************************** hpadu-7.30-6.linux.rpm - HP Array Diagnostics Utility for Linux, v7.30-6 Enhancements Added support for the following: Smart Array P600 controller. Active-Active on redundant controllers that support it. ******************************** hp_qla2x00src-7.05.00-9.linux.rpm - HP StorageWorks FCA2214/FCA2214DC FC HBA Driver for 2.4.x Kernels, v7.05.00-9 Fixes Resolved the following: Random i/o errors To recognize HP-* initrd names Do not configure tape or media changer devices for failover Enhancements Added the following: Toggle_debug_flag script New driver version, 7.05.00 ******************************** fibreutils-1.10-5.linux.i386.rpm - Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (x86), v1.10-5 Fixes Resolved boot from SAN panic issue where hp_rescan was removing XP devices. Updated to not execute "scsi remove-single-device" on Red Hat Enterprise Linux 4; This resulted in i/o errors. ******************************** fibreutils-1.10-5.linux.x86_64.rpm - Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (AMD64/EM64T), v1.10-5 Fixes Resolved boot from SAN panic issue where hp_rescan was removing XP devices. Updated to not execute "scsi remove-single-device" on Red Hat Enterprise Linux 4; This resulted in i/o errors. ******************************** lsicsb6-2.50d-14.ul10.i586.rpm - HP ProLiant CSB-6 ATA-100 IDE RAID Driver for UnitedLinux 1.0, v2.50d-14 Enhancements Updated to add support for new Linux errata kernels. ******************************** ucdsnmp-cmaX-4.2.6-220.ul10.i386.rpm - A Collection of SNMP Protocol Tools from UC-Davis for SUSE LINUX Enterprise Server 8 (x86), v4.2.6-220 Enhancements Added support for new HP ProLiant Hardware. ******************************** ucdsnmp-cmaX-4.2.6-220.ul10.x86_64.rpm - A Collection of SNMP Protocol Tools from UC-Davis for SUSE LINUX Enterprise Server 8 (AMD64), v4.2.6-220 Enhancements Added support for new HP ProLiant Hardware. ******************************** hpasm-7.3.0-58.ul10.i386.rpm - HP System Health Application and Insight Management Agents for SUSE LINUX Enterprise Server 8 (x86), v7.3.0-58 Fixes Resolved an issue with the DL760G2 and DL740 where single bit memory errors were not being properly logged in the IML. Resolved an issue where the DIMM information was incorrectly displayed on the System Management Homepage. Enhancements Added support for new HP ProLiant Hardware. Included support for Red Hat Enterprise Linux 4 (original support released with hpasm version 7.2.1). Added support for HP Smart Array P600 controller. ******************************** hprsm-7.3.0-58.ul10.i386.rpm - HP Lights-Out Drivers and Agents for SUSE LINUX Enterprise Server 8 (x86), v7.3.0-58 Fixes Compound traps in cmarackd have been modified to display the correct oid for multiple objects. Enhancements Added support for new HP ProLiant Hardware. Included support for Red Hat Enterprise Linux 4 (original support released with hprsm version 7.2.1). ******************************** hpasm-7.3.0-58.ul10.x86_64.rpm - HP System Health Application and Insight Management Agents for SUSE LINUX Enterprise Server 8 (AMD64), v7.3.0-58 Fixes Resolved an issue with the DL760G2 and DL740 where single bit memory errors were not being properly logged in the IML. Resolved an issue where the DIMM information was incorrectly displayed on the System Management Homepage. Enhancements Added support for new HP ProLiant Hardware. Included support for Red Hat Enterprise Linux 4 (original support released with hpasm version 7.2.1). Added support for HP Smart Array P600 controller. ******************************** hprsm-7.3.0-58.ul10.x86_64.rpm - HP Lights-Out Drivers and Agents for SUSE LINUX Enterprise Server 8 (AMD64), v7.3.0-58 Fixes Compound traps in cmarackd have been modified to display the correct oid for multiple objects. Enhancements Added support for new HP ProLiant Hardware. Included support for Red Hat Enterprise Linux 4 (original support released with hprsm version 7.2.1). ******************************** cpq_cciss-2.4.54-14.ul10.i586.rpm - HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 8 (x86), v2.4.54-14 Enhancements Added support for the following: Latest errata support Smart Array P600 ******************************** cpq_cciss-2.4.54-14.ul10.amd64.rpm - HP ProLiant Smart Array Controller (AMD64) Driver for SUSE LINUX Enterprise Server 8 (AMD64), v2.4.54-14 Enhancements Added support for the following: Latest errata support Smart Array P600 ******************************** hpdiags-7.0.1-8.linux.i386.rpm - HP Insight Diagnostics Online Edition for Linux, v7.0.1-8 Fixes Fixed an issue where hpdiags could not be started on systems. The following error message occurred: "Forbidden You don't have permission to access /hpdiags/hpdiagsstart.php on this server. Additionally, a 403 Forbidden error was encountered while trying to use an ErrorDocument to handle the request. Enhancements Added support for the following: New ProLiant servers HP Smart Array P600 and SAS drives AMD Dual Core Processors ******************************** e100-3.3.6a-1.src.rpm - HP ProLiant NC31xx Fast Ethernet NIC Driver for Linux, v3.3.6a-1 Enhancements This driver now builds correctly on Red Hat Enterprise Linux 4. ******************************** e1000-5.7.6a-1.src.rpm - HP ProLiant NC 61xx/71xx/310x Gigabit Ethernet NIC Driver for Linux, v5.7.6a-1 Enhancements This driver supports the latest distributions listed in the text file. ******************************** bcm5700-7.4.12b-1.src.rpm - HP NC10xx/67xx/77xx/150x/320x Gigabit Ethernet NIC Driver for Linux, v7.4.12b-1 Enhancements This driver can no longer attempt to set speed and duplex on the NC150T embedded adapter. ******************************** vlan-1.8.0q-14.src.rpm - HP Tested and Approved Linux 802.1q VLAN Driver, v1.8.0q-14 Enhancements This package does not support Red Hat Enterprise Linux 4. Use the vlan_init package for Red Hat Enterprise Linux 4. This package has been tested with the specified errata kernels. ******************************** bonding-1.0.4t-1.src.rpm - HP Tested and Approved Linux Bonding Driver, v1.0.4t-1 Enhancements This package does not support Red Hat Enterprise Linux 4. The native bonding driver on Red Hat Enterprise Linux 4 is supported. This package has been tested with the specified errata kernels. ******************************** cmanic-7.3.0-4.sles8.linux.rpm - HP NIC Agents for SUSE LINUX Enterprise Server 8, v7.3.0-4 Enhancements Initial release. ******************************** hpsmh-2.0.2-109.linux.i386.rpm - HP System Management Homepage for Linux (x86), v2.0.2-109 Enhancements Added the following: Japanese Language Kit New index.html.* to pop-up when unsupported browser logs into HPSMH (Konqueror/FireFox) ******************************** hpsmh-2.0.2-109.linux.x86_64.rpm - HP System Management Homepage for Linux (AMD64/EM64T), v2.0.2-109 Enhancements Added the following: Japanese Language Kit New index.html.* to pop-up when unsupported browser logs into HPSMH (Konqueror/FireFox) ******************************** megaide-2.26j-14.ul10.i586.rpm - HP ProLiant Integrated Ultra ATA-100 Dual Channel Driver for UnitedLinux 1.0, v2.26j-14 Enhancements Updated to add support for new Linux errata kernels. ******************************** hponcfg-1.1.0-5.sles8.i386.rpm - HP Lights-Out Online Configuration Utility for UnitedLinux 1.0/SUSE LINUX Enterprise Server 8, v1.1.0-5 Enhancements Initial release. ******************************** hpvca-2.1.1-16.linux.rpm - Version Control Agent for Linux, v2.1.1-16 Enhancements Maintenance release for SmartStart 7.30. ******************************** cpqacuxe-7.30-9.linux.rpm - HP Array Configuration Utility for Linux, v7.30-9 Enhancements Added support for the following: Smart Array P600 controller. Active-Active on redundant controllers that support it. ******************************** Copyright 2003-2005 Hewlett-Packard Development Company, L.P.